My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
re: septic system
Orono
>
Property Files
>
Street Address
>
A
>
Abingdon Way
>
2340 Abingdon Way - 03-117-23-23-0015
>
Septic
>
re: septic system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:35:26 PM
Creation date
7/27/2015 1:44:04 PM
Metadata
Fields
Template:
x Address Old
House Number
2340
Street Name
Abingdon
Street Type
Way
Address
2340 Abingdon Way
Document Type
Septic
PIN
0311723230015
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> .� 0,�. <br /> .� O � O . <br /> '; -;�:���=��-� CITY of �R011T0 <br /> �� A�t�f.,�°�r�, � <br /> �1;,��;���,y(�1 'y,�' MunicipalOffices <br /> ��� `''�.;'����������G SVeet Address: � Mailin Address: <br /> � S <br /> ��'Eg�i�g 2750 Kelley Parkway P.O. Box 66� <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> Owner: �o�C' o�a C' 2�C� M�r k 0 w . Address: a.3 y d ��;�q d o n W� <br /> Cirs•Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every rivo years. <br /> The on-site se�ti•age treatment system at the above address has been inspected and appears to fall into the categories checked beloiv. <br /> SYSTEM CONFORMITY (1-3): ) <br /> �1 "CODE SYSTEM" An ISTS which meets all the locatioq design and cons4vction standards of tha current Orono Municipal Code. . <br /> 2 "COMPLIANT SYSTEM" An ISTS which does not meet aIl the location,design and constructioa staadards of the cuaent Orono�iunicipal <br /> Coda but does meet the threa foot separation requiremecrt,end which is not failing or aa imminent threat to public health or safety. <br /> 3 "NON-CONIPLIANT SYSTEM" A prolu'bited ISTS;aa ISTS located withia a designated 100-year flood plaia,any ISTS which may <br /> or may not meet all the location,design,or construction standards of the cuae�Orono Municipal Code and which is faiting for any reasoa;and <br /> any ISTS with less than three feet of unsaturatzd soil or sand between the distribution device and the limiting soil characteristics. <br /> TANK CONDITION(5-10): 6 <br /> Tank inspection indicates: - � <br /> � Pumpout not naeded at this tima. _ <br /> � Tacil:must be pumped out this year (city code requites tac�lcs to be pumped out every 3 yeacs. Tank was last pumped l�—a1�"' 9 7 ), <br /> 7 Solids ac�timulation in tanks is at a critical a crilicalleveL Tanks should be pumpad out as soon as possible. <br /> 3 SyStem is discharging to the surface. Tanks must ba pumped out within 48 houcs to elimutate surface dischazge. <br /> 9 Inspection risers missing-tanks could not be inspected, Inspection risets(4"dia.pipe)must be installed in each tank at next pumpout If tanks <br /> ha��a not bzen pumpad out within the last three years,tttey should be pumped out now. <br /> 1� Inspection pipa is located directly over tank ba$1e(does not give accurate measurecnent of solids aecumulation). If taaks have not been pumped <br /> out�vithin the last three years,thay should be pumpr.d out now. <br /> DRAINFIELD CONDITION(11-14): ` � <br /> i l Drainfield is dry,no surfacing evideert. � . . <br /> 12 Some e�-idence of surfacing,not critical yet � � � , <br /> 13 Drainfield"u saturated and visibly discharging untreatad effluent to the surface. Contact the City Inspector immediately.Repairs must be <br /> complttrd�rithiit 90 days. <br /> 1-� Draintield e�Zrnt and conditioa unknown � <br /> CO��Il�1ENTS: 5 ySfien. I b�K�S CS� <br /> �-�.� -� ► c��. �:v�,,� <br /> Date of Inspection Sepfic System Inspector <br /> Note: In the went that this inspzction repod is used to satisfy the requirements for a martgage or other transfer of property,be advised that ffiig report does noq gnaraertee <br /> or czrtify that an existing system will continue to function properly,but is merely an opinion ofthe adequacy of the system under cuaent conditions based oa the available <br /> informatioa <br />
The URL can be used to link to this page
Your browser does not support the video tag.