2017-00696 - septic new/replacement
Orono
>
Property Files
>
Street Address
>
W
>
West Farm Road
>
1860 West Farm Rd - 27-118-23-43-0018
>
Septic
>
2017-00696 - septic new/replacement
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:22:39 PM
Creation date
5/7/2020 12:59:38 PM
Metadata
Fields
Template:
x Address Old
House Number
1860
Street Name
West Farm
Street Type
Road
Address
1860 West Farm Road
Document Type
Septic
PIN
2711823430018
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INSPECTOR CHECKLIST - mound <br /> -,oou west -arm Road <br /> E.Li sel cka: 20'to pressure tested sewer line (5 psi for 15 min) <br /> 50'to everything 100'to dispersal area with shallow well <br /> :,<i)i c:it i. ,. i LINLS, <br /> Nl:5 ;etnack: 10'to everything <br /> R,- sethacr.: platted: 10'prop line. Metes 8 bounds: cut of road easement. or outer ditch. <br /> r setback: 20'for bluff. Lakes: GD , RD , NE . Protected Protected wetland . <br /> . <br /> i i;,:J!,craw: 10'for everything, 20'for dispersal area. <br /> \k A ER LINE unLter pressure s.10'to bed,tank a sewer tine. (else sewer tine> 12"below) <br /> Sewer line E baffle connection (no 90's, 3'between 45's, slope min 1" in 8', max 2"in 8') <br /> no depth req's, clean out every 100', Sch 40 pipe) <br /> Septic tank and risers (water tight, insulated, proper depth, existing verified by pumping) <br /> mfg 1500 gallons none <br /> • Riser over outlet, riser over inlet or center, and 6"+ inspection pipe over any remaining baffles. <br /> No effluent filter it alarm <br /> Jose tank risers and piping (water tight, insulated, proper depth, drainback) <br /> mfg 1000 gallons <br /> dose pump 29 gpm 25 nead VERIFY PUMP CURVE 5.4 m:r.ON 9 nr OFF <br /> coat setting drop 6.2 inches at 25.0 gpi "DESIGNED" 4.1 inches approx float tether length <br /> 156.0 gal dose divided by gpi "INSTALLED"= inches float drop (field corrected <br /> _ ..ABEL pump requirements and drawdown on riser or panel <br /> Cam lock reachable from grace-30"max. J-hook weep hole. Supply line access (no hard 90's) <br /> 1 2.0 rich supply pipe: Sch40. sloped 1/8"+, supported by 4"sch40 sleeve or compacted, and buried 6"?. <br /> fl splice box / control panel /electrical connections <br /> flow measurement: CT, ETM, time dosed, home water meter <br /> f' mound absorption area rough up <br /> mound rock dimensions 10.0 X 38.0 <br /> Sand lift depth 20 inches. (Jar test : 2"sand Leaves< 1/8"silt after 30 min) <br /> Absorption Sand beyond rock 0.0 upslope 17.0 downslope <br /> Berme° topsoil beyond rockbed 12 upslope 13 sideslope 21 downslope <br /> cover oeptr.of 12.18"" VERIFY <br /> Laterals (1-2'from edge of rock) <br /> 2.00 ncrn pipe size (Sch40 pipe(i fittings) <br /> 3.0 ft lateral spacing <br /> 11,4 inch perforations <br /> 3.0 ft perforation spacing <br /> Air inlet at end of laterals, and at top feed manifold if necessary. VERIFY <br /> clean outs (no nerd 90'si <br /> 4'inspection pipe to bottom of rock, anchored VERIFY <br /> A.andon existing system if necessary ;Re-use existing tank certification <br /> monitoring plan and type <br /> welt abandonment form - if necessary <br />