2017-00696 - septic new/replacement
Orono
>
Property Files
>
Street Address
>
W
>
West Farm Road
>
1860 West Farm Rd - 27-118-23-43-0018
>
Septic
>
2017-00696 - septic new/replacement
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:22:39 PM
Creation date
5/7/2020 12:59:38 PM
Metadata
Fields
Template:
x Address Old
House Number
1860
Street Name
West Farm
Street Type
Road
Address
1860 West Farm Road
Document Type
Septic
PIN
2711823430018
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Installer Summary <br /> ! 1500 gallon Septic tank (minimum) Tank options: none <br /> ----, 3un iarsger lanK wrt:r muu+pte uump/UV:Kb <br /> 000 ieatton Dose tank (minimum) at 25.00 gpi <br /> 29 !GPM g' i 25 ft. of head, Pump required <br /> i 6.2 iincn swing on Demand float which translates to roughly 4.1 inches of float tether length <br /> if time dosing is required -->i 5.4 minutes ON time& 9 hours OFF time <br /> 18 'inches from bottom of tank to"pump ON"float, or 1 12 inches to"timer ON"float <br /> 21 I incnes from bottom of tank to"Hi Level Alarm"or ( 31 inches to"Hi level alarm" if time dosed <br /> 255 ft. of r---- <br /> 2.0 finch supply line with end feed manifold connection <br /> (Tip: "top feed"manifold to control drainbackj <br /> 20 inch, or : 1.7lft. Sand Lift Mound <br /> I 10.0 Ift. wide by i 38.0 1ft. tong Rock bed <br /> 3 Itaterals .F 2.00 jincn diameter 36.0 ft. tong 3.0 ft. lateral spacing <br /> 1/4" !inch perfs ; 3.0 Ift. perforation spacing <br /> OEffluent fitter&alarm <br /> 3 ;clean out&valve box assemblies <br /> 2r 7.0 ft.Totat sand ABSORPTION width (minimum) <br /> 0.0 Ift. upslope and sideslope (sand beyond rockbed, minimum) <br /> 117.0 ft. Downslope ,_ -... r.,-- :_. -- -. .,- <br /> Specific slope ratios give BERM widths (topsoil beyond rockbed)of: <br /> jupstope ratio I 12 ft. upslope berm <br /> 3:1siaestope 13 (ft. sideslope berms <br /> 4:1 ,downslope i 21 ft. downslope berm <br /> 4" inspection pipe <br /> c18" cover on top <br /> { ; <br /> Upslope berm I 12 ! Downslope berm 21 <br /> immwdor <br /> _ - , - - ,r-�_` 12" cover on sides <br /> - __ �_ e_ _._.___. (6"loamy cap&6"topsoil) <br /> sly y 1.7 C;C', i s,.-i. 'f - _ <br /> 3 1.3 <br /> Ic Absorption Width 27.0 <br /> Note: <br /> For 0 to 1% slopes, Absorption Width is measured from the Bedequally in both directions. <br /> For slopes >1%, Absorption Width is measured downhill from the upslope edge of the Bed <br /> Roc►:Bea: 13.0 yd3 or*1.4= 18 ton 6 inches unoer pipe <br /> Mound Sand: 1 138 yd3 or`1.4= 193 ton calculation based on 3:1/4:1 slope from top of rockbe, <br /> Loamy Cap: 52 yd3jor•1.4= 73 ton 6"deep <br /> opsoil: ! 62 !yo-or"1.4= 87 ton 6"deep <br />