My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Nexseal Info
Orono
>
Property Files
>
Street Address
>
S
>
Shadywood Road
>
2380 Shadywood Road - 17-117-23-44-0111
>
Misc
>
Nexseal Info
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:46:20 PM
Creation date
5/6/2020 10:34:57 AM
Metadata
Fields
Template:
x Address Old
House Number
2380
Street Name
Shadywood
Street Type
Road
Address
2380 Shadywood Road
Document Type
Misc
PIN
1711723440111
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> Prior to Applying DC 315 to Ensure Proper Adhesion: Surfaces must General Safety,Toxicity,Health Data <br /> be clean, dry and free of all foreign matter.Adhesion of a coating to SPF Material Safety Data Sheets are available on this coating material. Any <br /> requires the foam surface to have a slight profile or texture similar to an individual who may come in contact with these products should read and <br /> orange peel. Smooth or glossy foam surfaces must be flash coated with a understand the M.S.D.S. In case of emergency contact CHEMTREC <br /> light 3 -4 mils Wet Film Thickness(WFT) of DC 315 and allowed to dry EMERGENCY NUMBER at 800-424-9300. <br /> before applying the full application. Flash coating is a quick burst of a <br /> primer or DC 315,via airless sprayer over an area needing treatment. We WARNING:Do not allow product to freeze.Store above 10°C(50°F)at all <br /> also recommend flash coating around all pipes and air ducts. times. <br /> Product Application WARNING: Avoid eye contact with the liquid or spray mist. Applicators <br /> In order to validate warranty and confirm the installation complies with should wear protective clothes,gloves and use protective cream on face, <br /> IFTI's best practices installer must obtain and read all current installation hands and other exposed areas. <br /> documents.Installation documents include Application Guide, EYE PROTECTION: <br /> Ventilation Guide and Job Work Report. Safety glasses,goggles,or a face shield are recommended. <br /> These documents can be downloaded at www.painttoprotect.com or by <br /> calling IFTI at 949.975.8588. "Job Work Records are an excellent way to SKIN PROTECTION: <br /> track your installations and confirm compliance to your Building Official or Chemical resistant gloves are recommended, cover as much of the <br /> Authority Having Jurisdiction. In the event of a concern on a job the exposed skin area as possible with appropriate clothing. <br /> installer is able to provide documented proof of the installation, for this <br /> reason IFTI recommends using these forms for all thermal barrier jobs." RESPIRATORY PROTECTION is MANDATORY! <br /> Respiratory protective equipment,impervious foot wear and protective <br /> Material Preparation clothing are required at all times during spray application. <br /> DC31S must be thoroughly mixed prior to application. Failure to do so will <br /> compromise the materials performance and may create issues with INGESTION:Do not take internally. <br /> equipment used for the application of the product. Mechanical stirring <br /> with a high speed drill and a paddle appropriate for the container size is Consider the application and environmental concentrations in deciding if <br /> recommended. Material should be stirred from the bottom up making additional protective measures are necessary. <br /> sure the bottom and sides are scraped with a paint stick during the mixing <br /> process to ensure all materials are completely mixed prior to the Limited Warranty <br /> application. Material should be mixed to a creamy consistency with no This product will perform as tested if applied and maintained according to <br /> lumps. Thinning is not usually needed, but if the material has been our directions, instructions and techniques. If this product is found to be <br /> exposed to prolonged periods of high temperatures during storage, defective upon inspection by its representative, the seller will, at its <br /> evaporation of the water based material may have taken place.Typically option,either furnish an equivalent amount of new product or refund the <br /> the liquid level should be about 3 inches from the top of the 5 gallon pail. purchase price to the original purchaser of this product.Seller will not be <br /> If the level of material is lower,water may be added during the mixing to liable for any representations made by any retail seller or applicator of the <br /> address this issue. product. THIS WARRANTY EXCLUDES (1) LABOR OR COST OF LABOR FOR <br /> THE APPLICATION OR REMOVAL OF THIS PRODUCT OR ANY OTHER <br /> Temperature and Humidity PRODUCT,THE REPAIR OR REPLACEMENT OF ANY SUBSTRATE TO WHICH <br /> Ensure temperature and humidity are within specified limits for THE PRODUCT IS APPLIED OR THE APPLICATION OF REPLACEMENT <br /> application. Failure to monitor and compensate for increased humidity PRODUCT, (2) ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES. OTHER <br /> may lead to blistering and/or delamination and will void warranty.Obtain LIMITATIONS APPLY.For the complete terms of the limited warranty,go to <br /> a ventilation guide prior to commencing installation. Ideal conditions are www.painttoprotect.com. Some states/provinces do not allow the <br /> 16°C-32°C(62°F to 90°F)and a maximum of 65%Relative Humidity. exclusion or limitation of incidental or consequential damages, so the <br /> above limitations may not apply to you.To make a warranty claim,write <br /> Ventilation to Technical Service, International Fireproof Technology, Inc., 17528 Von <br /> When spraying in enclosed spaces,regardless of size,adequate ventilation Karman Avenue, Irvine, CA 92614 or email Customer Service at <br /> is required to remove excess moisture from the application area.The use ptp@painttoprotectcom <br /> of fans may be required in some cases to ensure a minimum of 0.3 air <br /> changes per hour. Prior to starting a job please be sure to download a <br /> complete current ventilation guide at www.painttoprotect.com <br /> Rev:12/18/2014 5:17 PM <br /> Job Work Record Should be Filled Out For Each and Every Job.Completed Work Records Must be Submitted To workrecords@painttoprotect.com Within 10 <br /> Days of Job Completion. <br />
The URL can be used to link to this page
Your browser does not support the video tag.