My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Nexseal Info
Orono
>
Property Files
>
Street Address
>
S
>
Shadywood Road
>
2380 Shadywood Road - 17-117-23-44-0111
>
Misc
>
Nexseal Info
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:46:20 PM
Creation date
5/6/2020 10:34:57 AM
Metadata
Fields
Template:
x Address Old
House Number
2380
Street Name
Shadywood
Street Type
Road
Address
2380 Shadywood Road
Document Type
Misc
PIN
1711723440111
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�g4ROtlh <br /> F :i International Fireproof Technology, Inc. Paint To Protect TM <br /> / 17528 Von Karman Ave.Irvine,CA 92614 <br /> N- <br /> 949-975-8588 <br /> DC 315 applied over Spray Polyurethane Foam (SPF), if a coating has not passed a full scale test on a manufacturer's foam it <br /> is an Alternative Barrier System in "Section 2603.9 cannot be used on that foam;there are no exceptions in the IBC Code! <br /> • Special Approval" as a thermal barrier. To be approved Building Code Fire Performance Requirements for SPF: <br /> as an Alternative Barrier System, DC 315 is applied over The International Building Code (IBC) mandates that SPF be separated <br /> a manufacturer's SPF and tested to the criteria of an from the interior of the building by a 15 minute thermal barrier, or other <br /> Dot NFPA 286, UL 1715, UL 1040, or FM 4880 for duration approved covering. DC 315 passed certified NFPA 286 and UL 1715 test <br /> of 15 minutes by an accredited fire testing facility. over a variety of open and closed cell spray applied urethane foams that <br /> Products that pass an ignition barrier tested under AC were conducted by ISA certified testing facilities. All tests performed <br /> 377 Appendix X are not appropriate alternative comply with the requirements of 2006 IBC Section 803.2.1 & 2009 IBC <br /> thermal barriers and cannot be used. Depending on your particular Section 803.1.2,and Section 2603.9;2012 IBC Section 803.1.2 and Section <br /> application, either ignition or thermal barriers are required by the 2603.10 under "Special Approvals for Thermal Barriers over Foam <br /> International Building Code (IBC). Plastics". DC315 is WHI marked and certified via 3`d party inspection for <br /> Properties Value quality assurance and consistency. <br /> Finish Flat Alternative 15 min Thermal Barrier Assemblies(e.g.Exposed SPF or SPF <br /> with a Thermal Barrier Protective Covering) <br /> Color Ice Grey The assembly must remain in place for 15 minutes during specified large- <br /> V.O.C. 47g/L scale fire tests,such as NFPA 286,UL 1715,UL 1040,or FM 4880. <br /> Solids By Volume 67% Alternative Ignition Barrier Assemblies DC 315 meets the requirements <br /> for ignition barrier per AC 377,Appendix X <br /> Specific Gravity 1.30+/-0.05 g/cc <br /> Application Equipment <br /> Drying Time @77°F &50% R.H. To touch 1—2 hours, to DC 315 can be applied by brush,roller or airless sprayer. <br /> recoat if required 2 to 4 hours For maximum yield and coverage spray application is recommended. <br /> Flash Point None Sprayers: <br /> Reducing or Cleaning Water Pump: (Graco)UltraMax 695 or equivalent <br /> PSI: 3000 <br /> Shelf Life 1 year from date of manufacture in unopened <br /> containers and stored at 1 0°C to 27°C(50°F to GPM: 1.00 <br /> 80°F) Tip: 517-521 or equivalent. <br /> 5 Gal.Container Weight 58 lbs. Filter: 30 mesh, removal of filter is recommend from gun and <br /> machine <br /> Advantages of Using DC315 SPF Hose: 3/8"diameter airless spray line for the first 100'from pump <br /> and%"x 3'whip <br /> ■ DC 315 is the only 3`d party inspected fire protective coating for SPF Pump: (Grace)TexSpray Mark 5 or equivalent <br /> • Marked and Listed by Warnock Hersey Intertek W/N 20947 PSI: 3300 <br /> • Single coat coverage reducing labor and material costs equaling GPM: 1.35 <br /> higher profits <br /> Industry leading spread rate Tip: 517 523 or equivalent. <br /> • Passed CAL 1350-safe for use in schools and high occupancy Filter: 30 mesh, removal of filter is recommend from gun and <br /> • buildings machine <br /> • Passed strict EPA—V.O.C.and AQMD air emission requirements(for Hose: 3/8"diameter airless spray line for the first 100'from pump <br /> all 50 states) and 14"x 3'whip <br /> ■ Approved for Incidental Food Contact complies with NSF/ANSI-51 <br /> requirements of USDA Pump: (Grace)GMAX 7900 or equivalent <br /> • Easily applied with a sprayer,roller,or brush with no complicated PSI: 3300 <br /> mixing GPM: 2.2 <br /> • 1 year shelf life Tip: 517-529 or equivalent. <br /> ■ Fast and easy clean-up,with no waste and fast turnaround time Filter: 30 mesh,removal of filter is recommend from gun and <br /> • Compatible with any paintable construction material machine <br /> • Meets Life Safety Code 101 Hose: 3/8"diameter airless spray line for the first 100' 300' from <br /> • Meets LEED's point requirements pump and%"x 3'whip <br /> • No formaldehyde <br /> Pump: (Graco)GH 833 or equivalent <br /> DC 315 is the most tested and approved product in the world for use as PSI: 4000 <br /> an,"Alternative Thermal Barrier Coating System"over Spray GPM: 4.0 <br /> Polyurethane Foam(SPF). <br /> Tip: 517-529 or equivalent. <br /> Filter: 30 mesh, removal of filter is recommend from gun and <br /> Visit us at our website www.painttoprotect.com to obtain a current matrix machine <br /> of all the manufacturer's foams DC 315 has been tested and approved as Hose: 3/8"diameter airless spray line for the first 100'-300' from <br /> Thermal or Ignition barriers in compliance with current IBC codes. pump and'/<"x3'whip <br />
The URL can be used to link to this page
Your browser does not support the video tag.