My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2017-01460 - new structure
Orono
>
Property Files
>
Street Address
>
P
>
Pinehurst Court
>
680 Pinehurst Court - 06-117-23-33-0015
>
Permits/Inspections
>
2017-01460 - new structure
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:27:13 PM
Creation date
5/4/2020 8:17:23 AM
Metadata
Fields
Template:
x Address Old
House Number
680
Street Name
Pinehurst
Street Type
Court
Address
680 Pinehurst Ct
Document Type
Permits/Inspections
PIN
0611723330015
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Section B <br /> Ventilation Method <br /> • <br /> (Choose either balanced or exhaust only) <br /> glanced,HRV(Heat Recovery Ventilator)or ERV(Energy Recov- 0 Exhaust only <br /> etyVentilator)—cfmafunitinlowmustnotexceedcontinuousventi- Continuous fan rating In cfm <br /> lation rating by more than 100%. - <br /> Low dm: 7 High cfm: Zo 0 Continuous fan rating in cfna(capacity must not exceed <br /> continuous ventilation rating by more than 100%) . <br /> • Directions-Choose the method of ventilation,balanced or exhaust only. Balanced ventilation systems are typically HRV or SRV's. <br /> Enter the low and high cfrn amounts. Low¢m airflow must be equal to or greater than the required continuous ventilation rote and <br /> less than 100%greater than the continuous rate.(For instance,if the low cfm is 40 cfm,-the ventilation fan must not exceed 80 cfm.) <br /> Automatic controls may allow the use of a largerfan that is operated a percentage of each hour. <br /> Section C • <br /> Ventilation Fan Schedule <br /> Description Location Continuous Intermittent <br /> , it A 7_;>w-,tt ,,- ( ;,'\Com, rt.)--t0- <br /> \i - k. �c14c.0-\-- ` rp c'c'� <br /> • Directions-The ventilation fan schedule should describe what the fan is for,the location,cfm,and whether it Ls used for continuous <br /> or intermittent ventilation. The fan that is chose for ca ntinuous ventilation must be equal to or greater than the low cfm air rating <br /> and less than 100%greater than the continuous rate. (For instance,if the low cfm is 40 cfm,the continuous ventilation fan must not <br /> exceed 80 cfm.) Automatic controls may allow the use of a larger fan that is operated a percentage of each hour-. . <br /> Section D - <br /> . - Ventilation Controls <br /> kik` • (Describe operation and control of the continuous and intermittent ventilation) <br /> O r j c ir- Cif 61'�-4 ."&d ) k, L-.- 44LGc.S6'- <br /> Directions-Describe the operation of the ventilation system. There should be adequate detail for plan reviewers and Inspectors to verify design and <br /> installation compliance. Related trades also need adequate detail for placement of controls and proper operation of the building ventilation. If <br /> exhaust fans are used for building ventilation,describe the operation and location of any controls,indicators-and legends. If an ERV or HRV is to be <br /> installed,describe how it will be Installed.If it will be connected and interfaced with the air handling equipment,please describe such connections as <br /> detailed in the manufactures'installation instructions If the installation instructions require or recommend the equipmentto be interlocked with the <br /> air handling equipment for proper operation,such interconnection shall be mode and described. • <br /> • <br /> Section E <br /> Make-up air J2 3 1 -f fca (' <br /> Passive(determined from calculations from Table 50L3.1) <br /> Powered(determined from calculations from Table S0L3.1) - <br /> Interlocked with exhaust device(determined from calculation from Table 5013.1) <br /> Other,describe: . - <br /> Location of duct or systerin ventilation make-up air:Determined om make-up air opening table <br /> •1‘.041 'Cfl` - , Via. Size and type(round,rectangular,flex or rigid) <br /> (NR means not required) - "'''��i � ` <br /> • <br /> Page 2 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.