Laserfiche WebLink
• <br /> Ventilation, Makeup and Combustion Air Calculations <br /> - • Submittal Form For New Dwellings <br /> Site address C0f1V ), LA c . /.{��' 1'4{) Date to 21.1 <br /> Contractor td/act Completed �"" <br /> y, t <br /> Section A <br /> Ventilation Quantity <br /> (Determine quantity by using Table N1104.2 or Equation 11-1) <br /> Square feet(Conditioned area including /a/ • <br /> Basement—finished orunfinished) . Total required ventilation / c C./ <br /> Number of bedrooms , 110 7 5 Continuous ventilation 7S` - <br /> Directions-Determine the total and continuous t entilation JJrate by either using Table N1104.2 or equation n-i. ' <br /> The table and equation are below. <br /> Table N1104.2 - - <br /> • <br /> Total and Continuous Ventilation Rates(in cfm) - <br /> • Number of Bedrooms - <br /> 1 2 - 3 4 - 5 6 • - <br /> Conditioned space(in Total/., Total/ Total/ Total/ Total/ Total/ <br /> sq.ft.) continuous continuous continuous continuous continuous continuous <br /> 1000-1500 .60/40 75/40 90/45 105/53 120/60 135/68 <br /> 1501-2000 70/40 85/43 100/50 115/58 _130/65 145/73 <br /> 2001-2500 80/40 95/48 _110/55 125/63 140/70 155/78 <br /> 2501-3000 90/45 105/53 _ 120/60 135/68 150/75 165/83 <br /> 3001-3500 _ 100/50 115/58 ' x130/65 145/73 160/80 175/88 <br /> 3501-4000 110/55 125/63 140/70 155/78 170/85 185/93 - <br /> 4001-4500 120/60 135/68 150/75 165/83. 180/90 195/98 <br /> 4501-5000 130/65 145/73 160/80 175/88 190/95 205/103 ' <br /> 5001-5500 140/70 155/78 170/85 185/93 200/100 215/108 <br /> 5501-6000 150/75 165/83 180/90 195/98 _210/105 225/113 <br /> Equation 11-1 <br /> (0.02 x square feet of conditioned space)+[15 x(number of bedrooms+1)1=Total.ventilation rate(cfm) <br /> i Conditioned space includes the basement. <br /> 2 If conditioned space exceeds 6000 sq. ft,_or there are more.than 6 bedrooms, use <br /> Equation 11-1 from Section N1104.2 to calculate total ventilation rate. <br /> Total ventilation—The mechanical ventilation system shall provide sufficient outdoor air to equal the total ventilation rate average, <br /> for each one-hour period according to the above table or equation. For heat recovery ventilators(HRV)and energy recovery ventila- <br /> tors(ERV)the average hourly ventilation capacity must be determined in consideration of any reduction of exhaust or out outdoor <br /> air intake,or both,for defrost or other equipment cycling. <br /> Continuous ventilation-A minimum of 50 percent of the total ventilation rate,but not less than 40 cfm,shall be provided,on a con- <br /> tinuous rate average for each one-hour period. The portion of the mechanical ventilation system intended to be continuous may <br /> have automatic cycling controls providing the average flow rate for each hour is met. • <br /> Page 1 of 6 <br />