• <br /> • <br /> 310.9.1 Smoke detectors. <br /> 310.9.1.1 General.Dwelling uni.ts,•congregate residences and hotel or lodging house guest <br /> rooms'that are used for sleeping purposes shall be provided with smoke.detectors. Detectors shall <br /> installed in accordance with the approved manufacturer's instructions. <br /> • <br /> 310.9.1.2 Additions, alterations or repairs to Group R Occupancies.When the valuation of an <br /> addition,alteration or repair to a Group P.Occupancy exceeds $1,000 and a permit is required, or <br /> when oneor more sleeping rooms are added•or created in existing Group R Occupancies, smoke <br /> detectorsshallbe installed in accordance with Sections 310.9.1.3, 310.9.1.4 and 310.9.1.5 of this <br /> section. <br /> EXCEPTION:Repairs to the exterior surfaces of a Group R'Occupancy are exempt from the rt <br /> ments of this section. <br /> • <br /> 310.9.1.3 Power source. In new construction, required smoke detectors shall receive their pri- <br /> mary power from the building wiring when such wiring is served from a commercial source and <br /> shall be equipped with a battery backup. The detector shall emit a signal when the batteries are <br /> Wiring shall be permanent and without a disconnecting switch other than those required for ov, <br /> current protection. Smoke detectors may be solely battery operated when installed in existing <br /> buildings; or in buildings without commercial power; or in buildings which undergo alterations, <br /> repairs or additions regulated by Section 310.9.1.2. <br /> • <br /> 310.9.1.4 Location within dwelling units. In dwelling units, a detector shall be installed in ea <br /> sleeping room and at a point centrally located in the corridor or area giving access to each sepa- <br /> sleeping area.When the dwelling unit has more than one story and in dwellings basement_ <br /> detector shall be installed on each story and in the basement. In dwelling units where a story o- <br /> rient is split into two or more levels, the smoke detector shall be installed on the upper level, e_ <br /> that when the lower level contains a sleeping area, a detector shall be installedFon each level.V <br /> sleeping rooms are on an upper level, the detector shall be placed at the ceiling of the upper le' <br /> close proximity to the stairway. In dwelling units where the ceiling height of a room open to th <br /> hallway serving the bedrooms exceeds that of the hallway by 24 inches (610 min) or more, smo <br /> detectors shall be installed in the hallway and in the adjacent room. Detectors shall sound an : <br /> audible in all sleeping areas of the dwelling unit in which they are located. <br />