216 SEWING <br /> ' I 1 McGUIRE RESIDENCE I j <br /> HEAT LOSS AND GAIN CALCULATIONS FOR INDIVIDUAL SPACES + <br /> ROOM: 1216 SEWING I ! j 'HEIGHT: 8.5 <br /> FLOOR 2 AREA: 99 VOLUME: 842 <br /> OCCUPANTS: 0 j <br /> HEAT LOSS <br /> ELEMENT AREA X MULTIPLIER = I BTU/HR <br /> ROOF ! 99 S.F 2.21Btu/Hr/S.F 218 ` <br /> DOORS 0 " 57111 ! - 1 <br /> WINDOWS 25 57 " I 1,425 i <br /> WALLS j 60 " ! 5 " I ! 3001 <br /> FOUNDATION 0 7.5 " - <br /> INFILTRATION* ! 4 CFM 102.6 Btu/Hr/CFM 1 360 <br /> j j TOTAL: 2,303 <br /> VENTILATION** 0 CFM 102.61 Btu/Hr/CFM 1 - <br /> I I !TOTAL 2,303 1 <br /> 1 I <br /> !HEAT GAIN SENS. LATENT 'TOTAL <br /> ROOF 99 S.F. i 0.92 I Btu/Hr/S.F. I 91 91 <br /> DOORS S&W 0 !" 1001 I - i - <br /> DOORS 1N&E 0 1" 91 - ) - <br /> WINDOWS S&W 0 " 1 1001 " - I - <br /> WINDOWS N 25 " 91 " 225 1 225 <br /> WINDOWS E 0 1601 " - 1 - <br /> WALLS S&W 0 !" j 1.91 " - <br /> WALLS N 60 (" ! 0.81 " ! I 48 1 48 <br /> WALLS E 0 0.81 <br /> LIGHTS 1 99 3.4151*** I 1 338 338 <br /> EQUIPMENT 0 1KW 34151Btu/kw 1 - i - <br /> OCCUPANTS 0 **** 300/3001 j - <br /> INFILTRATION 1 4 CFM 16/251Btu/hr/CFM j 56 : 88 ! 144 <br /> I � I 1 ITOTAL: 758 88 ; 846 <br /> VENTILATION I 0 CFM 16/25 Btu/hr/CFM 1 I - - - <br /> 1TOTAL: L 7581 881 846 <br /> NOTES: I I <br /> i <br /> Infiltration based on 1/4 air changes per hour 1 <br /> ***Lighting heat gain based on 1 watt per square foot ! 1 j 1 <br /> **Ventilation based on 2 CFM per S.F. Bathroom or Laundry j 1 i <br /> ****Occupants normally in continuous use of area I ! 1 <br /> Sensible and Latent load-based on light activity unless noted otherwisei j <br /> Page 1 <br />