215 BATHROOM <br /> { � McGUIRE RESIDENCE <br /> HEAT LOSS AND GAIN CALCULATIONS FOR INDIVIDUAL SPACES r <br /> ROOM: 1215 BATHROOM j HEIGHT: I 8.5 <br /> FLOOR 21 1 i I AREA: 105 1VOLUME: 893 <br /> OCCUPANTS: 01 1 1 <br /> HEAT LOSS <br /> ELEMENT AREA$ X MULTIPLIER 1= BTU/HR j <br /> ROOF 1 105 IS.F 2.2 Btu/Hr/S.F 231 <br /> DOORS 1 0 " 57 " 1 - <br /> WINDOWS 15 57 1 855 <br /> WALLS 1 i 28 1" 5 140 <br /> FOUNDATION 0 7.5 - <br /> INFILTRATION* 4 CFM 1 102.6 Btu/Hr/CFM 1 382 , <br /> 1 `TOTAL: 1,608 <br /> VENTILATION** 1 210 CFM 102.61Btu/Hr/CFM j 21,5461 <br /> ( TOTAL 23,154) <br /> ' I <br /> 1 (HEAT GAIN SENS. LATENT 1TOTAL <br /> ROOF 1 105 1S.F. 0.92 Btu/Hr/S.F. 97 97 <br /> DOORS S&W 0 I" I 1001 " I $ - - <br /> DOORS 1N&E 1 0 " 9$ " j - - <br /> i <br /> WINDOWS S&W 0 1" 1 1001 I1 1 - - <br /> WINDOWS N 15 �" 9 " 1 j 1 135 135 <br /> WINDOWS E • 0 1 601 " i - - <br /> WALLS 1 S&W 0 1.91 1 - - <br /> WALLS N 28 0.81 " 22 22 <br /> WALLS 1 E 0 1 0.81 " I - 1 - <br /> LIGHTS I 105 ! 3.4151*** 1 359 359 <br /> EQUIPMENT 1 0 1KW 34151Btu/kw L - - <br /> OCCUPANTS 0 '**** i 300/300$ <br /> INFILTRATION 4 ;CFM 16/251Btu/hr/CFM 60 93 152 <br /> , 1TOTAL: 1 672 93 765 <br /> VENTILATION 210 CFM 16/25 Btu/hr/CFM 3,360 5,250 8,610 <br /> TOTAL: 4,032 I 5,343 I 9,375 <br /> NOTES: <br /> Infiltration based on 1/4 air changes per hour <br /> ***Lighting heat gain based on 1 watt per square foot <br /> **Ventilation based on 2 CFM per S.F. Bathroom or Laundry : <br /> **** Occupants normally in continuous use of area 1 !1 <br /> Sensible and Latent load-based on light activity unless noted otherwise) <br /> Page 1 <br />