203 HALLWAY <br /> j 1 ! McGUIRE RESIDENCE j <br /> HEAT LOSS AND GAIN CALCULATIONS FOR INDIVIDUAL SPACES <br /> ROOM: 1203 HALLWAY I !HEIGHT: 8.5 1 <br /> FLOOR 2 j j AREA: 207 (VOLUME:! 1,760 <br /> OCCUPANTS: 0 <br /> HEAT LOSS <br /> ELEMENT AREA X MULTIPLIER 1= BTU/HR <br /> ROOF j 207 S.F ! 2.21Btu/Hr/S.FI 455 <br /> DOORS 1 0 57 " 1 - j <br /> WINDOWS 48 " 57 " 1 2,7361 <br /> WALLS ) j 114 j 5 " 1 570 <br /> FOUNDATION 0 7.5 " 1 - <br /> INFILTRATION* I 7 CFM j 102.6 Btu/Hr/CFM 1 752 j <br /> I TOTAL: 4,514 <br /> VENTILATION** 0 CFM 102.6 Btu/Hr/CFM - l <br /> 1 j TOTAL 4,514 <br /> • <br /> 1 1 1HEAT GAIN JSENS. LATENT 'TOTAL <br /> ROOF j I 207 1S.F. 0.92 Btu/Hr/S.F. 190 1 190 <br /> DOORS 'S&W 0 j" i 100 " 1 -- <br /> DOORS 1 N&E 0 I 91 0 f - <br /> WINDOWS S&W 0 1" 100 " j i - 1 - <br /> WINDOWS N 48 " 9 " 432 432 <br /> WINDOWS E 0 601 " - - <br /> WALLS j S&W 0 1.91 - <br /> WALLS IN 114 1" 0.8 " I 91 j 91 <br /> WALLSIE 1 0 1 0.8 - <br /> LIGHTS 1 0 1" 3.415j*** ? j - _ <br /> EQUIPMENT 0 !KW 34151Btu/kw - - <br /> OCCUPANTS 0 l**** 300/3001 - - - <br /> INFILTRATION j 7 1CFM 16/25iBtu/hr/CFM 117 183 301 <br /> 1 j ;TOTAL: j 831 183 1,014 <br /> VENTILATION 0 ;CFM 1 16/251Btu/hr/CFM - 1 _ - <br /> TOTAL: I 831 I 183 I 1,014 <br /> NOTES: <br /> Infiltration based on 1/4 air changes per hour • <br /> ***Lighting heat gain based on 1 watt per square foot 1 1 <br /> **Ventilation based on 2 CFM per S.F. Bathroom or Laundry <br /> ****Occupants normally in continuous use of area 1 <br /> *****Sensible and Latent load-based on light activity unless noted otherwisei <br /> Page 1 <br />