My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1997 - 009416 - fuel storage
Orono
>
Property Files
>
Street Address
>
W
>
Woodhill Road
>
200 Woodhill Road - 02-117-23-12-0001 Country Club
>
Permits/Inspections
>
1997 - 009416 - fuel storage
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:06:15 PM
Creation date
2/25/2020 12:10:38 PM
Metadata
Fields
Template:
x Address Old
House Number
200
Street Name
Woodhill
Street Type
Road
Address
200 Woodhill Rd
Document Type
Permits/Inspections
PIN
0211723120001
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Aboveground Dispensing of Flammable/Combustible Liquids <br /> Notes <br /> The installation shall comply with the Minnesota Uniform Fire Code . <br /> The following are reference notes from the Minnesota Uniform Fire Code <br /> which contain specific instructions applicable to this project . These <br /> requirements must be complied with. <br /> 1 . The installation must be approved by the local fire chief . <br /> M.R. 7510 .3440 Subp. 5 <br /> Sec. 79 . 903 (a) <br /> When approved by the chief, the dispensing of Class I and <br /> Class II liquids from a fuel dispensing system supplied by <br /> exterior aboveground tanks may be permitted . . . <br /> 2 . Unless the tank is listed as meeting the requirements for <br /> secondary containment, the tank must be provided with a <br /> dike. <br /> 3 . The tank system must be listed for aboveground use . <br /> M.R. 7510 .3440 Subp. 5 <br /> Sec. 79 .903 (a) 2 : <br /> The tank system shall be listed as meeting UL 2085 <br /> requirements or approved for such aboveground use . <br /> 4 . Tanks must be provided with lightning protection. <br /> M.R. 7510 .3440 Subp. 5 <br /> Sec. 79 . 903 (a) 10 : <br /> Tanks shall be provided with lightning protection as <br /> specified in National Fire Protection Association Standard <br /> 78, Lightning Protection Code, 1989 . <br /> 5 . Safety rules and signs . <br /> Sec. 79 .903 (d) : <br /> Conspicuous signs prohibiting smoking, prohibiting <br /> dispensing into unapproved containers, and requiring vehicle <br /> motors to be stopped during fueling operations shall be <br /> posted within sight of each customer being served. <br /> 6 . The location and size of the required fire extinguisher shall be <br /> shown on the plot plan. <br /> Sec. 79 . 908 <br /> A fire extinguisher with a minimum rating of 2A2OBC shall <br /> 1 <br />