Laserfiche WebLink
Sep 07 04 11 : 02p TOM LINDEMEIER 952 361 6918 p. 4 <br /> REScheck Inspection Checklist <br /> 2000 Minnesota Energy Code <br /> REScheckSoftware Version 3.6 Release I <br /> DATE:09/07/04 <br /> PROJECT TITLE: John Van Dyck residence <br /> PLAN REVIEW AND INSPECTION ISSUES <br /> This list of items may be helpful for Plan Reviewers and Building Inspectors to use as a guide for enforcing the Minnesota <br /> Energy Code. The items apply to Group R Division 3 Occupancies,one-and two-family residential dwellings. The <br /> items marked with*apply only to detached one-and two-family residential dwellings. <br /> PLAN REVIEW ISSUES <br /> FOUNDATION INSPECTION <br /> [ ] foundation wall insulation R-5 minimum <br /> [ ) foundation insulation extends from top of wall down to top of the footing <br /> [ ) exterior foundation insulation is covered by a protective coating finish <br /> CONCRETE SLAB OR UNDER-SLAB INSPECTION <br /> ( ) slab on grade perimeter insulation R-5 minimum <br /> [ I slab insulation extends from top of slab to design frost line or top of footing <br /> [ ) floors over unheated space R-30 minimum <br /> WINDOWS/DOORS/SKYLIGHTS <br /> [ ) average U-value is 0.37 maximum for windows and glass doors(excludes foundation windows) <br /> [ ] window U-values consistent with building plan and REScheckCertificate <br /> [ ] window and door areas consistent with building plan and REScheckCertificate <br /> MECHANICAL VENTILATION ISSUES <br /> [ ) residential mechanical ventilation system provides adequate ventilation per code requirements* <br /> [ ] furnace efficiency is consistent with REgheckCertificate or building plan <br /> [ ) protection against excessive depressurization is installed per code requirements* <br /> ENVELOPE INSULATION FOR PLAN REVIEW <br /> [ ) interior basement insulation R-5 minimum(if no exterior insulation) <br /> [ ) ceilings with attics R-38 minimum or consistent with building plan and RES checkCertificate <br /> [ ] wall framing and insulation level is consistent with building design and REScheckCertificate <br /> INSPECTION ISSUES <br /> CONCEALED INSULATION <br /> Framing and Sheathing <br /> ( ] wind wash barrier installed at attic edge <br /> [ ] exterior wall corners framed so that insulation can be installed after exterior sheathing is installed <br /> [ ) intersections of interior partition walls and exterior walls framed so that insulation can be installed between the <br /> partition and exterior sheathing after exterior sheathing is installed <br /> [ ) gaps between framing less than one-half inch are eliminated by securing framing together or are insulated at the time <br /> of assembly <br />