CITY OF ORONO O <br /> Municipal Offices 1 :1 <br /> kir\ <br /> Post Office Box 66 '-=- p <br /> k. <br /> Crystal Bay, MN 55323-0066 t ON—SITE SEWAGE TREATMENT <br /> 1$4 , III 1�. INSPECTION REPORT <br /> kESHO�' <br /> Owner: \JO/16 /44128 (,$ Address: Z H5 a'OCc! 141iN/J /.2/7-1.1/T- (55350 <br /> Permit C's: 6 J Z 66 Dates: if(0Z8/8/ Contractors: b/-(CIii 3'ii <br /> City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the category <br /> checked below. <br /> (This is, an existing system ( ) new construction) <br /> SYSTEM CONFORMITY (1-3): 3 <br /> 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City <br /> Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input <br /> without discharging any pollutants into ground or surface waters. <br /> 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the <br /> current City Codes, but was installed according to the code in effect at the time of installation, and which <br /> is operating satisfactorily by treating and disposing of the entire current sewage input without discharging <br /> /' any pollutants into ground or surface waters. <br /> y 3) "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any <br /> �� system which may or may not meet all the location, design, and construction standards of the current City <br /> Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand <br /> between the distribution device and the limiting soil characteristics. <br /> (The limiting soil characteristic has or ( ) has not been identified at this time. If the limiting soil <br /> characteristic has not been ident fied, this classification may be subject to revision.) <br /> TANK CONDITION (5-10): a <br /> T inspection indicates: <br /> Pumpout not needed at this time. <br /> Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. <br /> 7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. <br /> C12)System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. <br /> Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each <br /> tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pumped <br /> out now. <br /> 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). <br /> If tanks have not been pumped out within the last three years, they should be pumped out now. <br /> DRAINFIELD CONDITION (11-14): 0 <br /> Drainfield inspection indicates: <br /> 11 Drainfield is dry, no surfacing evident. <br /> Some evidence of surfacing, not critical yet. <br /> (ft!) <br /> Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately. Repairs must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> LIMITING SITE FACTORS (slope,setbacks,etc.): w 4.i.z_-7it_lritE <br /> POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): �i /C ;r7 <br /> • <br /> COMMENTS: ///oLi44Cf iS d i_scha I(1q ririe it ( (.letri. J5' Sfe..•s71 /1J e 7c9 hC/ <br /> r y)elLQ- O w>114 v' 'O cf ay.c � Ie O (#y rot. PAis -Or ( /'{y �/60r ,Y <br /> r 4" (91461— ybOC) . <br /> Date of Inspection S is System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of <br /> property, be advised that this report does not guarantee or certify that an existing system will continue to function <br /> properly, but is merely an opinion of the adequacy of the system under current conditions based on the available <br /> information. <br /> This report must be kept on the premises with the system location and pumping records. <br /> WHITE COPY/Inspectors File YELLOW COPY/Homeowner <br />