Laserfiche WebLink
Jesse Struve <br /> II <br /> COPT <br /> From: Jesse Struve OhIb6 a/ <br /> Sent: Wednesday, August 22, 2012 11:58 AM <br /> To: Melanie Curtis <br /> Cc: Christine Mattson <br /> Subject: 20120822 1050 Willow View Drive <br /> Melanie, <br /> I have reviewed the application for 1050 Willow View Drive and have the following comments: <br /> • The retaining walls are shown to be less than 4' which do not require engineered plans and specifications. If <br /> things change during construction and the walls are constructed which exceed 4' or if tiered walls are installed <br /> which exceed 4' or are not separated by more than 2x the height of the walls(as measured from the face of the <br /> upper wall to the back of the lower wall),the applicant will be required to submit these plans. <br /> • The applicant will need to follow the recommendations for the wetland buffer area as outlined by the Bolton & <br /> Menk letter dated August 16, 2012. <br /> Please contact me with any questions or concerns. <br /> Jesse Struve, PE <br /> Director of Public Works/City Engineer <br /> City of Orono <br /> (952) 249-4661- Direct <br /> (952) 249-4616- Fax <br /> www.ci.orono.mn.us <br /> 1 <br />