Laserfiche WebLink
EXERCISE POINT <br /> TJ-Beam^' 6555 Serial Number:700103477 2 Pcs of 1.75" x 9.5" 2.0E MicroIlam® LVL <br /> BEAMUSA 1111 221/02 9:17.14 AM <br /> Page 1 of 1 Budd Code:146 <br /> THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN CONTROLS FOR THE APPLICATION AND LOADS LISTED <br /> 4- <br /> 14' <br /> Product Diagram Is Conceptual. <br /> LOADS: <br /> Analysis for Header Member Supporting FLOOR-RES.Application. Tributary Load Width: 1' <br /> Loads(psf):40 Live at 100%duration;15 Dead;0 Partition; and: <br /> TYPE CLASS LIVE DEAD LOCATION APPLICATION COMMENT <br /> Point(lbs.) Floor(1.00) 0 1279 3' Adds to <br /> SUPPORTS: INPUT BEARING REACTIONS(Ibs.) <br /> WIDTH LENGTH LIVE/DEAD/TOT. PLY DEPTH DETAIL OTHER <br /> 1 Beam 3.50" 2.25" 277/1178/1455 1 9.5" Detail A3 1.25"LSL Rim <br /> 2 2x6 Plate 5.50" 4.25" 283/440/723 1 9.5" Detail A3 1.25"LSL Rim <br /> -See TJ SPECIFIER'S/BUILDER'S GUIDES for detail(s):A3. <br /> DESIGN CONTROLS: <br /> MAXIMUM DESIGN CONTROL CONTROL LOCATION <br /> Shear(Ib) 1444 1385 6317 Passed(22%) Lt.end Span 1 under Floor loading <br /> Moment(ft-lb) 3833 3833 13156 Passed(29%) MID Span 1 under Floor loading <br /> Live Defl.(in) 0.063 0.338 Passed(U999+) MID Span 1 under Floor loading <br /> Total Defl.(in) 0.243 0.675 Passed(U666) MID Span 1 under Floor loading <br /> -Deflection Criteria:STANDARD(LL: U480,TL:L/240). <br /> -Bracing(Lu):All compression edges(top and bottom) must be braced at 2'8"o/c unless detailed otherwise. Proper attachment and <br /> positioning of lateral bracing is required to achieve member stability. <br /> ADDITIONAL NOTES: <br /> -IMPORTANT! The analysis presented is output from software developed by Trus Joist(TJ). TJ warrants the sizing of its products by this <br /> software will be accomplished in accordance with TJ product design criteria and code accepted design values. The specific product <br /> application, input design loads, and stated dimensions have been provided by the software user, This output has not been reviewed by <br /> a TJ Associate. <br /> -Not all products are readily available. Check with your supplier or TJ technical representative for product availability. <br /> -THIS ANALYSIS FOR TRUS JOIST PRODUCTS ONLY! PRODUCT SUBSTITUTION VOIDS THIS ANALYSIS. <br /> -Allowable Stress Design methodology was used for Code UBC analyzing the TJ Residential product listed above. <br /> -Note: See TJ SPECIFIER'S/BUILDER'S GUIDES for multiple ply connection. , <br /> PROJECT INFORMATION OPERATOR INFORMATION: <br /> No Project Information available D.F.P.Planning&Design <br /> Terry Mikkelson <br /> 4797 highway 10 n.e. <br /> arden hills, mn 55112 <br /> 651-636-6889 <br /> 651-638-1412 <br /> Copyright®2000 by Trus Joist,a Weyerhaeuser Business TJ-Pro'and TJ-BeamTM are trademarks of Trus Joist. <br /> Micrnllam®in a registered trademark of Trus Jn«' <br />