Laserfiche WebLink
�-. REC RM POINT <br /> era <br /> S.:.iv.ro <br /> TJ-BeamT" s555 Serial Number 700103477 3 Pcs of 1.75" x 11.875" 2.0E Microllam® LVL <br /> BEAMUSA 1111 2f21/02 9 15.44 AM <br /> Page 1 0'1 Build Code.146 <br /> THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN CONTROLS FOR THE APPLICATION AND LOADS LISTED <br /> 1 <br /> '12; <br /> 20' <br /> Product Diagram is Conceptual. <br /> LOADS: <br /> Analysis for Header Member Supporting FLOOR-RES.Application. Tributary Load Width: 1' <br /> Loads(psf):40 Live at 100%duration; 15 Dead;0 Partition;and: <br /> TYPE CLASS LIVE DEAD LOCATION APPLICATION COMMENT <br /> Point(Ibs.) Floor(1.00) 0 3864 14'3" Adds to <br /> SUPPORTS: INPUT BEARING REACTIONS(Ibs.) . <br /> WIDTH LENGTH LIVE/DEAD/TOT. PLY DEPTH DETAIL OTHER <br /> 1 Column 5.25" 4" 403/1430/1833 1 11.9" Detail A3 1.25"LSL Rim <br /> 2 Beam 3.50" 2.25" 397/3079/3476 1 11.9" Detail A3 1.25"LSL Rim <br /> -See TJ SPECIFIER'S/BUILDER'S GUIDES for detail(s):A3. <br /> DESIGN CONTROLS: <br /> MAXIMUM DESIGN CONTROL CONTROL LOCATION <br /> Shear(Ib) 3464 3383 11845 Passed(29%) Rt.end Span 1 under Floor loading <br /> Moment(ft-lb) 18213 16657 26922 Passed(62%) MID Span 1 under Dead load <br /> Live Defl.(in) 0.093 0.488 Passed(U999+) MID Span 1 under Floor loading <br /> Total Defl.(in) 0.734 0.976 Passed(U319) MID Span 1 under Floor loading <br /> -Deflection Criteria: STANDARD(LL: L/480, TL:L/240). <br /> -Bracing(Lu):All compression edges(top and bottom)must be braced at 2'8"o/c unless detailed otherwise. Proper attachment and <br /> positioning of lateral bracing is required to achieve member stability. <br /> ADDITIONAL NOTES: <br /> -IMPORTANT! The analysis presented is output from software developed by Trus Joist(TJ). TJ warrants the sizing of its products by this <br /> software will be accomplished in accordance with TJ product design criteria and code accepted design values. The specific product <br /> application,input design loads,and stated dimensions have been provided by the software user. This output has not been reviewed by <br /> a TJ Associate. <br /> -Not all products are readily available. Check with your supplier or TJ technical representative for product availability. <br /> -THIS ANALYSIS FOR TRUS JOIST PRODUCTS ONLY! PRODUCT SUBSTITUTION VOIDS THIS ANALYSIS. <br /> -Allowable Stress Design methodology was used for Code UBC analyzing the TJ Residential product listed above. <br /> -Note: See TJ SPECIFIER'S/BUILDER'S GUIDES for multiple ply connection. <br /> PROJECT INFORMATION OPERATOR INFORMATION: <br /> No Project Information available D.F.P.Planning&Design <br /> Terry Mikkelson <br /> 4797 highway 10 n.e. <br /> arden hills, mn 55112 <br /> 651-636-6889 <br /> 651-638-1412 <br /> Copyright C 2000 by Trus Joist,a Weyerhaeuser Business. TJ-Pro"'and TJ-Beam"'are trademarks of Trus Joist. <br /> Minrnllam®is a registered trademark of Trim Joist <br />