My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2014 - Soil & Percolation Testing
Orono
>
Property Files
>
Street Address
>
W
>
Willow Hill Drive
>
2360 Willow Hill Drive - 03-117-23-23-0023
>
Septic
>
2014 - Soil & Percolation Testing
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:35:44 PM
Creation date
2/13/2020 10:24:49 AM
Metadata
Fields
Template:
x Address Old
House Number
2360
Street Name
Willow Hill
Street Type
Drive
Address
2360 Willow Hill Dr
Document Type
Septic
PIN
0311723230023
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OSTP Pressure Distribution <br /> Minnesota Pollution UNIVERSITY ,?; <br /> Control Agency Design Worksheet OF MINNESOTA :''' +-�.��- <br /> 12. Calculate the Square Feet per Perforation. Recommended value is 4-11 ft 2 per perforation. <br /> Does not apply to At-Grades <br /> a. Bed Area = Bed Width (ft) X Bed Length (ft) <br /> 10 ft X 63 ft = 630 ft2 <br /> b. Square Foot per Perforation = Bed Area divided by the Total Number of Perforations. <br /> 630 ft2 ÷ 63 perforations - 10.0 ft2/perforations <br /> 13. Select Minimum Average Head: 1.0 ft <br /> 14. Select Perforation Discharge (GPM) based on Table: 0.56 GPM per Perforation <br /> 15. Determine required Flow Rate by multiplying the Total Number of Perfs. by the Perforation Discharge. <br /> 63 Perfs X 0.56 GPM per Perforation = 36 GPM <br /> 16. Volume of Liquid Per Foot of Distribution Piping (Table 11): 0.170 Gallons/ft <br /> 17. Volume of Distribution Piping = <br /> Table 11 <br /> = [Number of Perforated Laterals X Length of Laterals X (Volume of Volume of Liquid in <br /> Liquid Per Foot of Distribution Piping] Pipe <br /> Pipe Liquid <br /> 3 X 61 ft X 0.170 gal/ft = 31.1 Gallons Diameter Per Foot <br /> (inches) (Gallons) <br /> 18. Minimum Delivered Volume = Volume of Distribution Piping X 4 1 ' 0.045 <br /> 1.25 0.078 <br /> 31.1 <br /> gals X 4 = 124.4 Gallons 1.5 0.110 <br /> 2 0.170 <br /> manifold pipe` 3 0.380 <br /> 1 4 0.661 <br /> ' Cleanouts — _ <br /> pipe from pump <br /> L•----:........./ `' i Manifold pipes J <br /> dean outs - <br /> V • J <br /> alternate location '/ <br /> V of pipe from pump � — `�./`Alternate location <br /> ` of pipe from pump <br /> Pipe frompump <br /> Comments/Special Design Considerations: <br />