My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2014 - Soil & Percolation Testing
Orono
>
Property Files
>
Street Address
>
W
>
Willow Hill Drive
>
2360 Willow Hill Drive - 03-117-23-23-0023
>
Septic
>
2014 - Soil & Percolation Testing
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:35:44 PM
Creation date
2/13/2020 10:24:49 AM
Metadata
Fields
Template:
x Address Old
House Number
2360
Street Name
Willow Hill
Street Type
Drive
Address
2360 Willow Hill Dr
Document Type
Septic
PIN
0311723230023
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OSTP Pressure Distribution v <br /> Minnesota Pollution Design Worksheet UNIVERSITY !- <br /> Control Agency OF MINNESOTA ` Z`�� <br /> Project ID: v 06.12.13 <br /> 1. Media Bed Width: 10 ft <br /> 2. Minimum Number of Laterals in system/zone= Rouded up number of [(Media Bed Width - 4) : 3] + 1. <br /> ( 10 -4 ) + 1 = 3 laterals Does not apply to at-grades <br /> 3. Designer Selected Number of Laterals: 3 laterals <br /> Cannot be less than line 2 (accent in at-grades) .w--- <br /> 4. Select Perforation Spacing: 3.0 ft "''`-` ..1:-` NI_r <br /> 5. Select Perforation Diameter Size: 7/32 in - I^- ,.M4 <br /> 6. Length of Laterals = Media Bed Length - 2 Feet. <br /> 63 - 2ft = 61 ft Perforation can not be closer then 1 foot from edge. <br /> 7 Determine the Number of Perforation Spaces. Divide the Length of Laterals by the Perforation Spacing <br /> and round down to the nearest whole number. <br /> Number of Perforation Spaces = 61 ft 3 ft = 20 Spaces <br /> Number of Perforations per Lateral is equal to 1.0 plus the Number of Perforation Spaces. Check table <br /> 8. below to verify the number of perforations per lateral guarantees less than a 10%discharge variation. The <br /> value is double with a center manifold. <br /> Perforations Per Lateral = 20 Spaces + 1 = 21 Perfs. Per Lateral <br /> Maximum Number of Perforations Per lateral to Guarantee<10%Discharge Variation <br /> '''Inch Perforations 7/32 Inch Perforations <br /> Perforation Spacing(Feet) Pipe Diameter(Inches) Perforation Spacing Pipe Diameter(Inches) <br /> 1 1/ 111 2 3 (Feet) 1 1/ 11/2 2 3 <br /> 2 10 13 18 30 60 2 11 16 21 34 68 <br /> 21. 8 12 16 28 54 2/ 10 14 20 32 64 <br /> 3 8 12 16 25 52 3 9 14 19 30 60 <br /> 3.'16 Inch Perforations 118 Inch Perforations <br /> Pipe Diameter(Inches) Perforation Spacing Pipe Diameter(Inches) <br /> Perforation Spacing(Feet) <br /> 1 11/2 11 2 3 )Feet) I 1/ 1/ 2 3 <br /> 2 12 18 26 46 87 2 21 33 44 74 149 <br /> 2/ 12 17 24 40 80 2/ 20 30 41 69 135 <br /> 3 12 16 22 37 75 3 20 29 38 64 128 <br /> 9. Total Number of Perforations equals the Number of Perforations per Lateral multiplied by the Number of <br /> Perforated Laterals. <br /> 21 Perf. Per Lat. X 3 Number of Perf. Lat. = 63 Total Number of Perf. <br /> 10. Select Type of Manifold Connection (End or Center): 0 End ❑ Center <br /> 11. Select Lateral Diameter (See Table): 2.00 in <br />
The URL can be used to link to this page
Your browser does not support the video tag.