My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2014 - 00702 - septic new
Orono
>
Property Files
>
Street Address
>
W
>
Willow Hill Drive
>
2360 Willow Hill Drive - 03-117-23-23-0023
>
Permits/Inspections
>
2014 - 00702 - septic new
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:35:43 PM
Creation date
2/13/2020 9:47:47 AM
Metadata
Fields
Template:
x Address Old
House Number
2360
Street Name
Willow Hill
Street Type
Drive
Address
2360 Willow Hill Dr
Document Type
Permits/Inspections
PIN
0311723230023
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
f <br /> . OSTP Design Summary Worksheet UNIVERSITY <br /> Minnesota Pollution OF MINNESOTA <br /> Control Agency "ti\r <br /> Property Owner/Client: Jeff Et Paula Bata Project ID: v 06.12.13 <br /> Site Address: 2360 Willow Hill Drive,Orono,Hennepin County Date: 2/4/14 <br /> 1. DESIGN FLOW AND TANKS <br /> A. Design Flow: 750 Gallons Per Day(GPD) Note: The estimated design flow is considered a peak flow rate <br /> including a safety factor.For long term performance, the average <br /> B. Septic Tanks: daily flow is recommended to be<60%of this value. <br /> Minimum Code Required Septic Tank Capacity: 2250 Gallons,in 2 Tanks or Compartments <br /> Recommended Septic Tank Capacity: 2250 Gallons,in 2 Tanks or Compartments <br /> Effluent Screen: No Alarm: No <br /> C. Holding Tanks Only: <br /> Minimum Code Required Capacity: Gallons,in Tanks <br /> Designer Recommended Capacity: Gallons,in Tanks <br /> Type of High Level Alarm: <br /> D. Pump Tank f Capacity(Code Minimum): Gallons Pump Tank 2 Capacity(Code Minimum): Gallons <br /> Pump Tank I Capacity(Designer Rec): Gallons Pump Tank 2 Capacity(Designer Rec): Gallons <br /> Pump 1 36.0 GPM Total Head 25.1 ft Pump 2 GPM Total Head ft <br /> Supply Pipe Dia. 2.00 in Dose Volume: gal Supply Pipe Dia. in Dose Volume: gal <br /> 2. SYSTEM TYPE <br /> Type of Soil Treatment and Dispersal Area* ype of DismGuaon- <br /> Q Thendi Q Bed ()Mound 0 Gravity Dlstrbutlon 0 Pressure Distribution-Level 0 Pressure Dlstrbutlon-Unlevel <br /> Q Drip 0 Holding Tank 0 At-Grade *Selection Required Benchmark Elevation: 959.0 ft <br /> Benchmark Location: Test hole#1 <br /> System Type Type of Distribution Media: <br /> Q Type I ❑Type II 0 Type III 0Type I V 0 Type V Draintiekl Rock ❑Registered Treatment Media: <br /> 3. SITE EVALUATION: <br /> A. Depth to Limiting Layer: 24 in 2.0 ft B. Measured Land Slope%: 3.0 % <br /> C. Elevation of Limiting Layer: 958.9 D. Soil Texture: Loam <br /> E. Loc.of Restricive Elevation: F. Soil Hyd.Loading Rate: 0.60 GPD/ft2 <br /> G. Minimum Required Separation: 36 in 3.0 ft H. Perc Rate: 3.0 MPI <br /> I. Code Maximum Depth of System: Mound in Comments: <br /> 4. DESIGN SUMMARY <br /> Trench Design Summary <br /> Dispersal Area ft2 Sidewall Depth in Trench Width in <br /> Total Lineal Feet ft Number of Trenches Code Maximum Trench Depth in <br /> Contour Loading Rate ft Designer's Max Trench Depth in <br /> Bed Design Summary <br /> Absorption Area ft2 Media Below Pipe in Code Maximum Bed Depth in <br /> Bed Width ft Bed Length ft Designer's Max Bed Depth in <br />
The URL can be used to link to this page
Your browser does not support the video tag.