My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2013 - Soil & Percolation Testing
Orono
>
Property Files
>
Street Address
>
W
>
Willow Hill Drive
>
2300 Willow Hill Dr - 03-117-23-32-0026
>
Septic
>
2013 - Soil & Percolation Testing
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:36:49 PM
Creation date
2/12/2020 1:38:38 PM
Metadata
Fields
Template:
x Address Old
House Number
2300
Street Name
Willow Hill
Street Type
Drive
Address
2300 Willow Hill Dr
Document Type
Septic
PIN
0311723320026
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OSTP Pressure Distribution <br /> UNIVERSITY <br /> Minnesota Pollution Design Worksheet �OF MINNESOTA ? e <br /> "'" <br /> Control Agency `'�' <br /> Project ID: v 12.08.06 <br /> 1. Media Bed Width: 10 ft <br /> 2. Minimum Number of Laterals in system/zone=[(Media Bed Width(Line1)-4):3]+1 round up to the neareast whole number+1. <br /> ( 10 -4)+1 = 3 laterals <br /> 3. Designer Selected Number of Laterals: 3 laterals <br /> Cannot be less than line 2(accept in at-erades) <br /> mwmtea vi«+:w.. <br /> 4. Select Perforation Spacing: 3.0 ft - •--7- - <br /> Cent tIe :7- <br /> 5. Select Perforation Diameter Size: 7/32 in rwinimp n •` <br /> Yr'per(orations spaced 3'apart — t of rock / 1?- <br /> 6. Length of Laterals =Media Bed Length-2 Feet. 16-of rock / <br /> f trtor.tHon sizing:'r.-to`l." pe.Iotanon spacing:z'to 3' <br /> 63 - 2ft = 61 ft Perforation can not be closer then 1 foot from edge. <br /> 7 Determine the Number of Perforation Spaces. Divide the Length of Laterals (Line 6)by the Perforation Spacing (Line 4)and <br /> round down to the nearest whole number. <br /> Number of Perforation Spaces = 61 ft - 3 ft = 20 Spaces <br /> Number of Perforations per Lateral is equal to 1.0 plus the Number of Perforation Spaces (Line 7). Check table below to verify the <br /> 8' number of perforations per lateral guarantees less than a 10%discharge variation. The value is double with a center manifold. <br /> Perforations Per Lateral = 20 Spaces + 1 = 21 Perfs. Per Lateral <br /> Maximum Number of Perforations Per Lateral to Guarantee<10%Discharge Variation <br /> '/,Inch Perforations 7132 Inch Perforations <br /> Pipe Diameter(Inches) Perforation Spacing Pipe Diameter(Inches) <br /> Perforation Spacing(Feet) 1 114 11/2 2 3 (Feet) 1 114 11/2 1 3 <br /> 2 10 13 18 30 60 2 11 16 21 34 68 <br /> 2/ 8 12 16 28 54 2/ 10 14 20 32 64 <br /> 3 8 12 16 25 52 3 9 14 19 30 60 <br /> 3/16 Inch Perforations 1/8 Inch Perforations <br /> Pipe Diameter(Inches) Perforation Spacing Pipe Diameter(Inches) <br /> Perforation Spacing(Feet) 1 11/4 11 2 3 (Feet) t 114 ri: 2 3 <br /> 2 12 18 26 46 87 2 21 33 44 74 149 <br /> 212 12 17 24 40 80 21 20 30 41 69 135 <br /> 3 12 16 22 37 75 3 20 29 38 64 128 <br /> 9. Total Number of Perforations equals the Number of Perforations per Lateral (Line 8)multiplied by the Number of <br /> Perforated Laterals (Line 3). <br /> 21 Perf. Per Lateral X 3 Number of Perf. Laterals = 63 Total Number of Perf. <br /> 10. Select Type of Manifold Connection (End or Center): Q End ❑ center <br /> 11. Select Lateral Diameter(See Table): 2.00 in <br />
The URL can be used to link to this page
Your browser does not support the video tag.