My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2017 - 00589 - siding
Orono
>
Property Files
>
Street Address
>
W
>
Willow Drive North
>
0041 Willow Drive North - 33-118-23-44-0031
>
Permits/Inspections
>
2017 - 00589 - siding
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:52:51 PM
Creation date
2/10/2020 1:18:46 PM
Metadata
Fields
Template:
x Address Old
House Number
41
Street Name
Willow
Street Type
Drive
Street Direction
North
Address
41 Willow Drive North
Document Type
Permits/Inspections
PIN
3311823440031
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
APPLICATION INSTRUCTIONS (CONT.) <br /> • For information on fastening LP SmartSide Lap products in high c) For rigid foam sheathing greater than 1"(25.4 mm),a minimum <br /> wind speed areas,refer to ICC-ES Report ESR-1301. 1-1/2"(38.1 mm)thick by 4"(101.6 mm)wide vertical strapping <br /> • Alternative Fastening Options for 8-inch only 38 Series Precision Lap or furring strip must be installed over the sheathing to provide <br /> Over Structural Sheathing and 24 in.OC Wall Framing a solid,level nailing base for the siding.The strapping must be <br /> securely fastened to structural framing spaced no greater than <br /> • The sheathing must be a minimum 7/16 in.thick- 16"OC(406 mm)with a minimum nail penetration of 1-1/2 inches <br /> ness with an APA The Engineered Wood Association trade- <br /> markthat contains the (38.1 mm)and a maximum nail spacing no greater than the width <br /> of the siding. <br /> consensus standard DOC PS2. <br /> Louisiana-Pacific will assume no responsibility for any damage or <br /> • The transverse windload design val- condition arising from the use of foam sheathing. <br /> ues in table 4 of the APA Product Report PR- <br /> N124 may be used when the following fasteners <br /> specifications are met. <br /> • 38 series precision lap must be fastened with: OVERLAP, CLEARANCE & NAILING SPACE <br /> • a minimum no.8 corrosion resistant tapered head wood <br /> screw with a maximum spacing of 12 in.on center with Figure 1 <br /> 1.5 in.screw penetration into each stud or... V. <br /> • a minimum 6d(0.99 in.shank diameter)corrosion resistant �, Min.3/4 in.nail <br /> J <br /> +4E7.110 <br /> a I spacing from top <br /> ring shank nail with a maximum spacing of 8 in.on center <br /> with 1.5 in.nail penetration into each stud. � Sheathing if Breathable <br /> 1 in.min. required weather <br /> • Alternative Fastening Options Over SIP Assemblies: overlap <br /> • The sheathing must be a minimum 7/16 in.thickness with barrier <br /> an APA The Engineered Wood Association trademark that Sidin must extendSiding must not <br /> Siding 11,!-I3., ,,:,:ontact7asonr,y <br /> contains the consensus standard DOC PS2 below plate <br /> • The transverse windload design values in table 4 of the APA 741 4x <br /> Product Report PR-N124 may be used when the following Min.6 in. <br /> fasteners specifications are met. finish grade .. <br /> clearance <br /> • 38 series precision lap must be fastened with: <br /> • a minimum no.8 corrosion resistant tapered head wood <br /> screws with a maximum spacing of 12 in.on center or... <br /> • a minimum 6d(0.99 in.shank diameter)corrosion resistant <br /> ring shank nail with a maximum spacing of 8 in.on center <br /> • 76 series precision lap must be fastened with: BUTT JOINTS <br /> • a minimum no.8 corrosion resistant tapered head wood Figure 2 <br /> screw with a maximum spacing of 16 in.on center or... <br /> • a minimum 6d(0.99 in.shank diameter)corrosion resistant Nail min.3/4 in.from top <br /> ring shank nail with a maximum spacing of12 in.on center. and 3/8 in.from edge <br /> CAUTION 1 1 <br /> • Do not force siding into place. �� N �• <br /> • <br /> • DO NOT USE STAPLES. • � � �� <br /> Insulated Sheathings <br /> LP SmartSide Sidings may be installed over low-compression rigid <br /> foam or fiberglass sheathings.The following precautions must be <br /> followed: <br /> a) Adequate bracing of the wall in accordance with the Internation- • A minimum 3/16 in.gap is required at butt joints. <br /> al Codes or other ruling building code is required. • Seal all gaps at butt joints. <br /> b) For rigid foam sheathing up to 1"(25.4 mm)thick,siding may be • Unsheathed walls require adequate bracing. <br /> nailed directly to the foam sheathing unless a drainage plane <br /> is required by the local building code.Nail length must be in- • Joints must occur over the studs. <br /> creased to ensure a minimum 1-1/2"(38.1 mm)fastener penetra- <br /> tion into the structural framing. <br />
The URL can be used to link to this page
Your browser does not support the video tag.