My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2017 - 00589 - siding
Orono
>
Property Files
>
Street Address
>
W
>
Willow Drive North
>
0041 Willow Drive North - 33-118-23-44-0031
>
Permits/Inspections
>
2017 - 00589 - siding
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:52:51 PM
Creation date
2/10/2020 1:18:46 PM
Metadata
Fields
Template:
x Address Old
House Number
41
Street Name
Willow
Street Type
Drive
Street Direction
North
Address
41 Willow Drive North
Document Type
Permits/Inspections
PIN
3311823440031
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Technical Evaluation Report(TER) <br /> 8. Findings: <br /> 8.1. When used and installed in accordance with this TER and the manufacturer's installation instructions, <br /> HeadLOK fasteners are acceptable for use as an alternative material, design and method of construction for <br /> the attachment of furring, sheathing or cladding over foam sheathing and into wood framing. <br /> 8.2. HeadLOK fasteners evaluated herein and installed in accordance with this TER meet the requirements of the <br /> 2003, 2006 and 2009 IRC for positive and negative wind pressure resistance. <br /> 8.3. HeadLOK fasteners evaluated herein and installed in accordance with this TER meet the requirements of the <br /> 2003, 2006 and 2009 IRC for lateral shear strength to support cladding materials installed over foam <br /> sheathing. <br /> 8.4. HeadLOK fasteners evaluated herein and installed in accordance with this TER meet the requirements of the <br /> 2003, 2006 and 2009 IBC for positive and negative wind pressure resistance. <br /> 8.5. HeadLOK fasteners evaluated herein and installed in accordance with this TER meet the requirements of the <br /> 2003, 2006 and 2009 IBC for lateral shear strength to support cladding materials installed over foam sheathing. <br /> 8.6. Use of HeadLOK fasteners to connect bracing materials in braced wall panels or shear walls is outside the <br /> scope of this TER. <br /> 9. Conditions of Use: <br /> 9.1. HeadLOK fasteners covered by this TER shall be installed in accordance with this report and the <br /> manufacturer's installation instructions. <br /> 9.2. HeadLOK fastener spacing shall not exceed Table 2 for the installation conditions considered. <br /> 9.3. For conditions not covered in this TER, connections shall be designed in accordance with accepted <br /> engineering practice. <br /> 9.4. Manufacturer's installation instructions shall be followed as provided in Section 6 and at <br /> www.fastenmaster.com/details/product/HeadLOK-heavy-dutv-flathead-fastener.html. <br /> 9.5. HeadLOK fasteners are produced by OMG, Inc. at their facility located in Agawam, Massachusetts. <br /> 9.6. HeadLOK fasteners are produced under a quality control program subject to periodic inspections in <br /> accordance with IBC Section 1703.5.2. <br /> 9.7. Install fasteners prior to utility installations in exterior walls to avoid accidental penetration of utilities(e.g. <br /> electrical wiring, plumbing, etc.). <br /> 9.8. Foam sheathing shall be minimum Type II (expanded polystyrene) or Type X(extruded polystyrene) per ASTM <br /> C578 or Type 1 (polyiso) per ASTM C1289. <br /> 9.8.1. Types with greater compressive strength are acceptable. <br /> 9.9. Ensure furring or sheathing material provides adequate substrate and thickness for the application of the siding <br /> fastener per code requirements for siding application and siding manufacturer's installation instructions. <br /> 9.9.1. For example, if the siding manufacturer requires the fastener for the siding to penetrate more than 3/4" into <br /> the furring, a 1"x 4"furring strip (actual dimension of 3/4"x 3%2")would not be adequate and a thicker <br /> furring strip, such as a 2"x 4", would be required. <br /> 10. Identification: <br /> 10.1. The fasteners are identified by the designation, "HeadLOKTM" on the packaging. The head of each fastener is <br /> marked with an "F"followed by a number corresponding to the length of the fastener. <br /> 10.2. The packaging shall include OMG's name and address, fastener size, third-party inspection agency and TER <br /> number. <br /> 10.3. Additional technical information can be found at the fastenmaster.com. <br /> TER No. 1009-01 Page 8 of 12 <br /> Use of FastenMaster HeadLOKTM Fasteners to Attach Cladding <br /> and/or Furring to Wood Framing through Foam Sheathing <br />
The URL can be used to link to this page
Your browser does not support the video tag.