My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2017 - 00589 - siding
Orono
>
Property Files
>
Street Address
>
W
>
Willow Drive North
>
0041 Willow Drive North - 33-118-23-44-0031
>
Permits/Inspections
>
2017 - 00589 - siding
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:52:51 PM
Creation date
2/10/2020 1:18:46 PM
Metadata
Fields
Template:
x Address Old
House Number
41
Street Name
Willow
Street Type
Drive
Street Direction
North
Address
41 Willow Drive North
Document Type
Permits/Inspections
PIN
3311823440031
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Technical Evaluation Report(TER) <br /> 6. Installation: <br /> 6.1. Add up the total thickness of furring, rigid insulation and sheathing then select the appropriate length of <br /> HeadLOK fastener(see Table 1)that will attach these combined materials and provide a minimum 2" <br /> penetration into the wood framing. <br /> 6.2. Using a high torque ''/2" drill, drive the HeadLOK through the center of the furring strip and into the insulation <br /> and wall framing. <br /> 6.3. Fasteners should be aligned so that the point engages the center of the wall stud and at a minimum distance of <br /> 3"from the end of the stud or furring material. <br /> 6.4. Fasteners must be installed in a manner to avoid over-driving yet snug enough to remove any gaps between <br /> the layers of materials being fastened <br /> 6.5. Figure 1 a and lb provide example graphics of two types of furring installations as a guide. <br /> 7. Test and Engineering Substantiating Data: <br /> 7.1. National Design Specification for Wood Construction—2005 Edition, American Forest&Paper Association <br /> (NDS). <br /> 7.2. General Dowel Equations for Calculating Lateral Connection Values(1999), TR-12, American Forest& Paper <br /> Association. <br /> 7.3. Testing conducted for the Foam Sheathing Coalition, the Steel Framing Alliance and the New York State <br /> Energy Research and Development Authority(NYSERDA)(Test Report). <br /> 7.4. Testing conducted for the Foam Sheathing Coalition by Progressive Engineering, Inc., Evaluation of Siding <br /> Attachment Methods Using Various Materials, Test Report#2010-128, dated 3/9/2010. <br /> 7.5. HeadLOK fastener design property calculations for HeadLOK Screws based on TR-12, NDS and NYSERDA <br /> reports, Crandell, 2010. <br /> 7.6. HeadLOK fastener performance from the FastenMaster Technical Bulletin for HeadLOK fasteners. <br /> 7.7. FastenMaster Installation instructions for HeadLOK fasteners. <br /> 7.8. Some information contained herein is the result of testing and/or data analysis by other sources, which DrJ <br /> relies on to be accurate as it undertakes its engineering analysis. <br /> 7.8.1. DrJ does not assume responsibility for the accuracy of data provided by testing facilities, but relies on <br /> each testing agency's accuracy and accepted engineering procedures, experience, and good technical <br /> judgment. <br /> 7.9. Where appropriate, DrJ relies on the derivation of design values, which have been codified into law through the <br /> codes and standards(e.g., IRC, WFCM, IBC, SDPWS, etc.), to undertake the review of test data that is <br /> comparative or shows equivalency to an intended end-use application. <br /> 7.9.1. DrJ does not assume responsibility for the accuracy of any code-adopted design values but relies upon <br /> their accuracy for engineering evaluation. <br /> 7.9.2. DrJ also relies on the fact that manufacturers of code-adopted products stand behind the legally <br /> established design values that have been created by the associations that publish code-defined design <br /> values for a given commodity product. <br /> 7.9.3. DrJ evaluates all equivalency testing and related analysis using this code-defined engineering foundation. <br /> TER No. 1009-01 Page 7 of 12 <br /> Use of FastenMaster HeadLOKTM Fasteners to Attach Cladding <br /> and/or Furring to Wood Framing through Foam Sheathing <br />
The URL can be used to link to this page
Your browser does not support the video tag.