My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Western Steel Erection plan review notes
Orono
>
Property Files
>
Street Address
>
W
>
Wayzata Boulevard West
>
2687 Wayzata Boulevard West - 33-118-23-13-0002
>
Misc
>
Western Steel Erection plan review notes
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:47:21 PM
Creation date
2/5/2020 1:55:39 PM
Metadata
Fields
Template:
x Address Old
House Number
2687
Street Name
Wayzata
Street Type
Boulevard
Street Direction
West
Address
2687 Wayzata Boulevard West
Document Type
Misc
PIN
3311823130002
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TABLE 3-B <br /> TABLE 3-C 1997 UNIFORM BUILDING CODE <br /> TABLE 3-B—REQUIRED SEPARATION IN BUILDINGS OF MIXED OCCUPANCY1(HOURS) <br /> A-1 A-2 A-2.1 A-3 A-4 B E F-1 _F2 _H2 H-3 H-4,5 H-6,7Z I M R-1 R-3 S-1 S-2 S-3 S-5 U-1 <br /> A-1 N N N N 3 N 3 3 4 4 4 4 3 3 1 1 3 3 4 3 l <br /> A-2 N N N 1 N 1 1 4 4 4 4 3 1 1 1 1 1 3 1 1 <br /> A-2.1 N N t I N I 1 4 —4 -4 4 3 1 1 1 1 1 3 l 1 <br /> ' A-3 N N I N I N N 4 4 4 3 2 N 1 1 N N 3 1 l <br /> A-4 I N 1 1 4 4 4 4 3 I 1 1 1 1 3 1 1 <br /> ' B 1 NS N 2 1 1 1 2 N 1 Ij N N 1 I I <br /> E 1 1 4 4 4 3 1 1 I -1 l I 3 1 1 <br /> IF-1 I 2 l 1 I 3 NS 1 I N N t I 1 <br /> F-2 2 1 1 1 2 1 I 1 N N 1 1 l <br /> H-1 — <br /> NOT PERMITTED IN MIXED OCCUPANCIES.SEE SECTION 307.2.8 <br /> H-2 1 1 24 2 4 4 2 2 2 2 1 <br /> H-3 1 l 4 1 3 3 l I 1 1 1 <br /> H-4,5 1 4 1 3 3 1 1 1 1 1 <br /> H-6,7T 4 1 4 4 1 1 F l 1 3 <br /> 2 1 1 2 2 4 3 I <br /> M 1 1 la 14 l 1 1 <br /> R-1 N 3 1 3 I <br /> R-3 1 <br /> l 1 1 1 1 <br /> S1 1 1 1 l <br /> S-2 1 l N <br /> S-3 1 I <br /> S-4 OPEN PARKING GARAGES ARE EXCLUDED EXCEPT AS PROVIDED IN SECTION 311.2 <br /> S-5 N <br /> N—No requirements for fire resistance. <br /> IFor detailed requirements and exceptions,see Section 302.4. 642-t 30Z.4 <br /> 217or special provisions on highly toxic materials,see the Fire Code. <br /> 3For agricultural buildings,see also Appendix Chapter 3. <br /> 4See Section 309.2.2 for exception. <br /> 7 5For Group F,Division 1 woodworking establishments with more than 2,500 square feet(232.3 m'-),the occupancy separation shall be one hour. <br /> TABLE 3-C—REQUIRED SEPARATION OF SPECIFIC-USE AREAS IN GROUP I, <br /> DIVISION 1.1 HOSPITAL AND NURSING HOMES <br /> DESCRIPTION OCCUPANCY SEPARATION <br /> 1. Employee locker rooms None <br /> 2. Gift/retail shops None <br /> 3. Handicraft shops None <br /> 4. Kitchens None <br /> 5. Laboratories that employ hazardous materials in quantities less than <br /> that which would cause classification as a Group H Occupancy One hour <br /> 6. Laundries greater than 100 square feet(9.3 m2)1 One hour <br /> 7. Paint shops employing hazardous substances and materials in <br /> quantities less than that which would cause classification as a Group H <br /> Occupancy One hour <br /> 8. Physical plant maintenance shop One hour <br /> 9. Soiled linen room) One hour <br /> 10. Storage rooms 100 square feet(9.3 m'-)or less in area storing <br /> combustible material None <br /> 11. Storage rooms more than 100 square feet(9.3 m'-)storing combustible <br /> material <br /> One hour <br /> 12. Trash-collectiorrioomsi One hour <br /> IFor rubbish and linen chute termination rooms,see Section 711.5. <br /> 1-34 <br />
The URL can be used to link to this page
Your browser does not support the video tag.