Laserfiche WebLink
Zoning File#2293 <br /> September 11, 1997 <br /> Page 7 <br /> of the park. <br /> 4. Lot 9 is proposed at 2.00 acres,but includes a private driveway easement. The City <br /> normally does not accept such easements for access across a property, but requires <br /> them to be platted as outlots (Section 11.31 Subd. 5). Also, the location of that <br /> private driveway in Lot 9 leaves little room between the driveway and the proposed <br /> septic system sites for house construction. The driveway should be an outlot. It <br /> should be relocated through a different portion of Lot 9. Lot 9 should contain 2 acres <br /> all on one side of the driveway, not split by it. Although these are 2 acre lots in 1 <br /> acre zone,their use of septic systems suggest that they should probably be developed <br /> to meet all of the 2 acre zone standards. <br /> 5. The proposed driveway from the westerly cul-de-sac to Lots 9 and 10 extends over <br /> Lots 8 and 11. Again that driveway easement should be an outlot. The area of the <br /> outlot must be excluded from the attributable areas of Lots 8 and 11. <br /> 6. Lots 4 and 7 contain a stormwater basin, and easements to accommodate that pond <br /> appear to have been correctly excluded from the net areas of Lots 4 and 7. The <br /> stormwater pond appears to be in the location that would take most of the natural <br /> drainage, and appears to be appropriately located. Please review the City Engineer's <br /> comments regarding drainage. <br /> 7. The City will require its standard 10'perimeter and 5' interior lot line drainage and <br /> utility easements. <br /> 8. Sheet 3 of 5 indicates the location of proposed houses on each lot, and their <br /> orientation. In Lots 6, 7 and 8, construction will involve the creation of a defined <br /> house pad, and in those lots the house locations will have only a minimum of <br /> flexibility. For the remaining 1 acre lots,the standard 35' front and rear, 10' side, 35' <br /> side street setbacks would apply. For the two 2 acre lots, staff would recommend <br /> that the standard 50' front and rear, 30' side setbacks be applied. The orientation of <br /> Lots 9 and 10 as to what is front, side and rear is unclear. <br /> 9. The City will require a Conservation and Flowage Easement over the wetlands in <br /> Lots 1, 2 and 3. It appears that it will be critical to determine the 929.4 contour for <br /> defining the lake shoreline, specifically in relation to the vacation request. <br /> 10. Lots 9 and 10 meet a 200' width standard for lots in the 2 acre zone. Lot 3 has a <br /> defined width of 120' measured along the 35' setback curve, or 142' measured in a <br /> straight line from side lot line to side lot line at the front setback line. However, Lot <br /> 3 is functionally 160'in width and if it is concluded a variance is required, it is staffs <br />