2015 - 01238 - septic system
Orono
>
Property Files
>
Street Address
>
W
>
White Oak Circle
>
2790 White Oak Circle - 04-117-23-42-0016
>
Septic
>
2015 - 01238 - septic system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:14:03 PM
Creation date
2/4/2020 9:29:44 AM
Metadata
Fields
Template:
x Address Old
House Number
2790
Street Name
White Oak
Street Type
Circle
Address
2790 White Oak Cir
Document Type
Septic
PIN
0411723420016
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OSTP Pressure Distribution111.-1:1\411111111'N—"•::','Minnesota Pollution Design Worksheet OF MINNESOTA UNIVERSITY <br /> Control Agency <br /> Project ID: v 07.14.15 <br /> 1. Media Bed Width: 10 ft <br /> 2. Minimum Number of Laterals in system/zone = Rounded up number of [(Media Bed Width - 4) : 3] + 1. <br /> ( 10 - 4 ) + 1 = 3 laterals Does not apply to at-grades <br /> 3. Designer Selected Number of Laterals: 3 laterals <br /> Cannot be less than line 2 (accept in at-grades) <br /> 4. Select Perforation Spacing: 3.0 ft I:, - -1,,,,:,,,,:::..-'1: <br /> ,.,.,, ::.rrr.1. <br /> / I•rl.rr..l r..n..rr..r.•.1..rr.rrr �M.rI rnt�rrr4 ��1)•_ <br /> 5. Select Perforation Diameter Size: 1/4 in —,_ j,. . , - ---- <br /> 6. Length of Laterals = Media Bed Length - 2 Feet. <br /> 50 - 2ft = 48 ft Perforation can not be closer then 1 foot from edge. <br /> 7 Determine the Number of Perforation Spaces. Divide the Length of Laterals by the Perforation Spacing <br /> and round down to the nearest whole number. <br /> Number of Perforation Spaces = 48 ft - 3 ft = 16 Spaces <br /> Number of Perforations per Lateral is equal to 1.0 plus the Number of Perforation Spaces. Check table <br /> 8. below to verify the number of perforations per lateral guarantees less than a 10% discharge variation. The <br /> value is double with a center manifold. <br /> Perforations Per Lateral = 16 Spaces + 1 = 17 Perfs. Per Lateral <br /> Maximum Number of Perforations Per Lateral to Guarantee<10%Discharge Variation <br /> 7.Inch Perforations 7/32 Inch Perforations <br /> Perforation Spacing(Feet) Pipe Diameter(Inches) Perforation Spacing Pipe Diameter(Inches) <br /> 1 1N 11/2 2 3 (Feet) 1 114 111 2 3 <br /> 2 10 13 18 30 60 2 11 16 21 34 68 <br /> 2/ 8 12 16 28 54 21t 10 14 20 32 64 <br /> 3 8 12 16 25 52 3 9 14 19 30 60 <br /> 3/16 Inch Perforations 1'8 Inch Perforations <br /> PerforationPipe Diameter(Inches) Perforation Spacing Pipe Diameter(Inches) <br /> Spacing(Feet) <br /> 1 1% 11/2 2 3 (Feet) t 114 11t 2 3 <br /> 2 12 18 26 46 87 2 21 33 44 74 149 <br /> 2/ 12 17 24 40 80 21/2 20 30 41 69 135 <br /> 3 12 16 22 37 75 3 20 29 38 64 128 <br /> 9. Total Number of Perforations equals the Number of Perforations per Lateral multiplied by the Number of <br /> Perforated Laterals. <br /> 17 Perf. Per Lat. X 3 Number of Perf. Lat. = 51 Total Number of Perf. <br /> 10. Select Type of Manifold Connection (End or Center): 2 End ❑ Center <br /> 11. Select Lateral Diameter (See Table): 2.00 in <br />
The URL can be used to link to this page
Your browser does not support the video tag.