My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1993 - Req. for rev. of septic sys. nonconformity
Orono
>
Property Files
>
Street Address
>
W
>
White Oak Circle
>
2700 White Oak Circle - 04-117-23-42-0021
>
Septic
>
1993 - Req. for rev. of septic sys. nonconformity
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:14:17 PM
Creation date
2/3/2020 9:06:32 AM
Metadata
Fields
Template:
x Address Old
House Number
2700
Street Name
White Oak
Street Type
Circle
Address
2700 White Oak Cir
Document Type
Septic
PIN
0411723420021
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> Xan Eeckhout Building Corporation Ka <br /> December 8, 1976 <br /> ` Page two <br /> In addition to the above percolation test holes, eight test borings (A-1 ,,rir <br /> through A-8) were drilled to a depth of 13 feet below the existing ground surface <br /> • <br /> to determine If the water table is less than that depth. According to the reed- <br /> ings listed on the log sheets, It is our opinion that the level of the longterm <br /> ground water table was located at a depth greater than 13 feet belowthe exist- <br /> . <br /> ing ground surface in most cases, and below a depth of 8 feet in all cases. <br /> Fluctuations in the water level may occur over a wide range, depending upon e' <br /> the amount of precipitation, evaporation and surface runoff which will vary <br /> with seasonal changes. <br /> Based on the test results, installation of individual soil absoprtion dis- <br /> posal systems should be acceptable for a recommended design rate of 60 minutes per <br /> inch. The observed water table in the area is at a depth greater than 6.5 feet <br /> below the existing ground surface, making an absorption system acceptable accord- <br /> ing to state code regulations. <br /> The provisions of the "Ordinance and Code Regulating Individual Sewage Dis- <br /> posal Systems" (1971) , as recommended by the Minnesota Department of Health, as <br /> well as any local ordinances and codes, should be followed in the design and in- <br /> stallation of the disposal systems. <br /> If there are any questions with regard to this report, please do not hesi- <br /> tate to contact us. <br /> I HEREBY CERTIFY THAT THIS PLAN,SPECIFICATION, Very truly yours, <br /> OR REPORT WAS PREPARED BY ME OR UNDER MY <br /> DIRECT SUPERVISION AND THAT I AM A DULY SOIL TESTING SERVICES OF MINNESOTA, INC. <br /> REGISTERED PROFESSIONAL ENGINEER UNDER THE <br /> :AWS OF THE STATE OF MINNESOTA.4222°""4"1"-- 3""'"-w--,9C2.444110 "-•. <br /> James H. Overtoom, P.E. <br /> DATED / REG NO.07e, L Registered Professional Engineer, Minnesota <br /> Enclosures: Soil Percolation Test Location Diagram <br /> Percolation Test Summary Sheets <br /> General Notes <br /> Unified Soil Classification System <br /> JHO/lw <br /> ., .M�«........+wr...i..ewA........r M........i.,.w.....J....,.a.w.,.....r.,54 •5,r.�..,.......w-,,,...,.. ..,. <br />