Laserfiche WebLink
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc <br /> Sabre Plumbing&Heating4)" SHIELDS-364 West Lake St Orono <br /> Plymouth,MN 55447 Page 5 <br /> System 2 Summary Loads <br /> C p0 nen t Area Sell Sen <br /> DescriptionQuan Loss Gain el <br /> ' Gan Gain <br /> LDK LOW EE: Glazing-Low EE Windows&Sliding Door 794.5 20,264 0 20,600 20,600 <br /> .30 U value .34 SHGC, u-value 0.3, SHGC 0.34 <br /> 11G: Door-Wood - Panel 48 2,203 0 674 674 <br /> 11J: Door-Metal - Fiberglass Core 24 1,224 0 374 374 <br /> 12E-Obw: Wall-Frame, R-19 insulation in 2 x 6 stud 1034.9 5,982 0 802 802 <br /> cavity, no board insulation, brick finish, wood studs <br /> 15A-10sffc-8: Wall-Basement, concrete block wall, R-10 347.4 1,328 0 30 30 <br /> foam board to floor, no framing, no interior finish, <br /> filled core, 8'floor depth <br /> RJ R13 Closed Cell: Wall-Frame, Custom, Spray Foam R- 657.5 4,246 0 870 870 <br /> 13 <br /> EXT R-10: Wall-Basement, Custom, Styrofoam to top of 724 6,153 0 0 0 <br /> footing- EXTERIOR PERIMETER-9' Basement <br /> 12E-Osw: Wall-Frame, R-19 insulation in 2 x 6 stud 1760.2 10,173 0 2,083 2,083 <br /> cavity, no board insulation, siding finish, wood studs <br /> 16B-50: Roof/Ceiling-Under Attic with Insulation on Attic 3252.1 5,529 0 3,252 3,252 <br /> Floor(also use for Knee Walls and Partition <br /> Ceilings), Vented Attic, No Radiant Barrier, Dark <br /> Asphalt Shingles or Dark Metal, Tar and Gravel or <br /> Membrane, R-50 insulation <br /> 21A-20: Floor-Basement, Concrete slab, any thickness, 2 3252.1 7,463 0 0 0 <br /> or more feet below grade, no insulation below floor, <br /> any floor cover, shortest side of floor slab is 20'wide <br /> Subtotals for structure: 64,565 0 28,685 28,685 <br /> People: 6 1,200 1,380 2,580 <br /> Equipment: 683 4,130 4,813 <br /> Lighting: 0 0 0 <br /> Ductwork: 3,128 754 906 1,660 <br /> Infiltration: Winter CFM: 142, Summer CFM: 0 12,913 0 0 0 <br /> Ventilation: Winter CFM: 280, Summer CFM: 280 10,160 5,896 1,793 7,689 <br /> Humidification (Winter) 28.87 gal/day : 10,589 0 0 0 <br /> AED Excursion: 0 0 926 926 <br /> System 2 Load Totals: 101,355 8,534 37,820 46,354 <br /> Check Figures �_.:, <br /> Supply CFM: 1,688 CFM Per Square ft.: 0.260 <br /> Square ft. of Room Area: 6,504 Square ft. Per Ton: 1,684 <br /> Volume (ft')of Cond. Space: 61,246 <br /> System Loads <br /> Total Heating Required Including Ventilation Air: 101,355 Btuh 101.355 MBH <br /> Total Sensible Gain: 37,820 Btuh 82 <br /> Total Latent Gain: 8,534 Btuh 18 % <br /> Total Cooling Required Including Ventilation Air: 46,354 Btuh 3.86 Tons(Based On Sensible + Latent) <br /> 1 Notes _ II <br /> Rhvac is an ACCA approved Manual J and Manual D computer program. <br /> Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at <br /> your design conditions. <br /> C:\ ...\LDK 364 West lake St Orono SHIELDS.rh9 Monday, February 17, 2014, 2:02 PM <br />