Knight Heating and Air Conditioning <br /> 13535 89th st. NE -Otsego, MN 55330 <br /> 763-274-9945- <br /> Whole House Heat Loss/Gain System I <br /> Van Pattens Sales Consultant: Ken Lien <br /> Proposal#: <br /> Orono, Date: 07/28/2010 <br /> Design Conditions: <br /> Winter Outdoor Temp. -20 Winter Indoor Design Temp: 70 <br /> Summer Outdoor Temp. 95 Summer Indoor Design Temp: 72 <br /> Loss/Gain Summary: <br /> Loss Gain <br /> Walls 7073 2069 Total BTUH Gain 23563 <br /> Windows 7340 4198 Capacity Multiplier 1.00 <br /> Doors 0 0 A/C Unit BTUH Rating 23563 <br /> Ceilings 3308 1694 <br /> Skylights 1197 2884 <br /> Floors 6903 1406 <br /> People/Kitchen 0 1800 <br /> Infiltration 18984 2426 Nominal A/C Unit Size* 2.0 <br /> Duct Loss/Gain 4481 1648 <br /> Total Sensible 49286 18125 Gas Furnace Output BTUH 49286 <br /> Total Latent 0 5438 <br /> Total 49286 23563 Electric Furnace KW 14.4 <br /> Calculations are Estimated values based on a Whole House Heat Loss/Gain analysis for a typical application. <br /> Please refer to our Room by Room program for atypical applications. <br /> *Equipment Selection should match Manufacturers Performance Data. (Latent and Sensible) <br />