Knight Heating and Air Conditioning <br /> 13535 89th st. NE -Otsego, MN 55330 <br /> 763-274-9945 - <br /> Whole House Heat Loss/Gain System I <br /> Van Pattens Sales Consultant: Ken Lien <br /> Proposal#: <br /> Orono, Mn Date: 07/28/2010 <br /> Design Conditions: <br /> Winter Outdoor Temp. -20 Winter Indoor Design Temp: 70 <br /> Summer Outdoor Temp. 95 Summer Indoor Design Temp: 72 <br /> Loss/Gain Summary: <br /> Loss Gain <br /> Walls 21614 4391 Total BTUH Gain 39653 <br /> Windows 17257 10784 Capacity Multiplier 1.00 <br /> Doors 1738 516 A/C Unit BTUH Rating 39653 <br /> Ceilings 3794 1943 <br /> Skylights 2095 5047 <br /> Floors 3062 0 <br /> People/Kitchen 0 2700 <br /> Infiltration 35067 5121 Nominal A/C Unit Size* 3.5 <br /> Duct Loss/Gain <br /> Total Sensible 84627 30502 Gas Furnace Output BTUH 84627 <br /> Total Latent 0 9151 <br /> Total 84627 39653 Electric Furnace KW 24.8 <br /> Calculations are Estimated values based on a Whole House Heat Loss/Gain analysis for a typical application. <br /> Please refer to our Room by Room program for atypical applications. <br /> *Equipment Selection should match Manufacturers Performance Data. (Latent and Sensible) <br />