Laserfiche WebLink
MMF-301(A) Mini,Monitor'Module Dimensions: 1.3'(3.302 cm)high x 2.75" (6.985 cm)wide x <br /> • Built-in type Identification automatically identifies this device0.65'(1.651 cm)deep. <br /> as a monitor module to the panel. Wire length:6'(15.24 cm)minimum. <br /> • Powered directly by two-wire SLC loop.No additional power <br /> required. MMF-302(A) Interface Module <br /> • High noise(EMF/RFI)Immunity. • Supports compatible two-wire smoke detectors. <br /> • Tinned,stripped leads for ease of wiring. • Supervises IDC wiring and connection of external power <br /> • Direct-dial entry of address:01 —159 on MS-9600 series source. <br /> panels,01—99 on other compatible systems • High noise(EMF/RFI)immunity. <br /> a <br /> • SEMS screws with clamping plates for ease of wiring. <br /> 1415 0 1 0 1 • Direct-dial entry of address: 01 —159 on MS-9600 series <br /> s S. . <br /> 2 2 panels,01 —99 on other compatible systems. <br /> - LED flashes during normal operation. <br /> 14 O 4 • LED latches steady to indicate alarm on command from <br /> 9 6 5 control panel. <br /> TENS ONES The MMF-302(A)Interface Module is intended for use in intelli- <br /> gent, addressable systems, where the individual address of <br /> each module is selected using built-in rotary switches. This <br /> module allows intelligent panels to interface and monitor two- <br /> wire conventional smoke detectors.It transmits the status(nor- <br /> 0 O _= U mal,open,or alarm)of one full zone of conventional detectors <br /> W ' Q back to the control panel. All two-wire detectors being moni- <br /> } " m tored must be UL compatible with the module. The MMF- <br /> 302(A) can be used to replace M302(A) modules in existing <br /> systems. <br /> MMF-302(A)APPLICATIONS <br /> Use the MMF-302(A) to monitor a zone of two-wire smoke <br /> The MMF-301(A) Mini Monitor Module can be installed in a detectors. The monitored circuit may be wired as an NFPA <br /> single-gang junction directly behind the monitored unit. Its Style B(Class B)or Style D(Class A)Initiating Device Circuit. <br /> small size and light weight allow it to be installed without rigid A 3.9 K ohm End-of-Line Resistor(provided) terminates the <br /> mounting. The MMF-301(A) is intended for use in intelligent, end of the Style B or D (class B or A)circuit(maximum IDC <br /> two-wire systems where the individual address of each module loop resistance is 25 ohms). Install ELR across terminals 8 <br /> is selected using rotary switches. It provides a two-wire initiat- and 9 for Style D application. <br /> ing device circuit for normally-open-contact fire alarm devices. <br /> The MMF-301(A)can be used to replace M301(A)modules in MMF-302(A)OPERATION <br /> existing systems. Each MMF-302(A) uses one of the available module <br /> MMF401(A)APPLICA TIONS addresses on an SLC loop. It responds to regular polls from <br /> the control panel and reports its type and the status(open/nor- <br /> Use to monitor a single device or a zone of four-wire smoke mal/short)of its Initiating Device Circuit(IDC).A flashing LED <br /> detectors,manual fire alarm pull stations,waterflow devices,or indicates that the module is in communication with the control <br /> other normally-open dry-contact devices.May also be used to panel. The LED latches steady on alarm (subject to current <br /> monitor normally-open supervisory devices with special super- limitations on the loop). <br /> visory indication at the control panel. Monitored circuit/device <br /> is wired as an NFPA Style B(Class B)Initiating Device Circuit. MMF-302(A)SPECIFICATIONS <br /> A 47K ohm End-of-Line Resistor(provided)terminates the cir- Nominal operating voltage:15 to 32 VDC. <br /> cuit. Maximum current draw:5.1 mA(LED on). <br /> MMF-301(A)OPERATION Maximum IDC wiring resistance:25 ohms. <br /> Each MMF-301(A) uses one of the available module Average operating current:300 IiA, 1 communication and 1 <br /> addresses on an SLC loop. It responds to regular polls from LED flash every 5 seconds,3.9k eol. <br /> the control panel and reports its type and the status(open/nor- <br /> mal/short)of its Initiating Device Circuit(IDC). EOL resistance:3.9K ohms. <br /> MMF-301(A) SPECIFICATIONS External supply voltage (between Terminals T3 and T4): <br /> DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms <br /> Nominal operating voltage:15 to 32 VDC, maximum.Current:90 mA per module maximum. <br /> Average operating current:350 pA, 1 communication every Temperature range:320F to 120°F(0°C to 490C). <br /> 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Humidity range:10%to 93%noncondensing. <br /> Shorted). <br /> Maximum IDC wiring resistance:40 ohms. Dimensions: 4.5' (11.43 cm) high x 4" (10.16 cm) wide x <br /> 125" (3.175 cm)deep. Mounts to a 4" (10.16 cm)square x <br /> Maximum IDC Voltage:11 Volts. 2.125"(5.398 cm)deep box. <br /> Maximum IDC Current:400 pA. <br /> EOL resistance:47K ohms. <br /> Temperature range:32•F to 120•F(0•C to 49•C). <br /> Humidity range:10%to 93%noncondensing. <br /> Page 2 of 4—DF-W121:C•10/06/2010 <br />