Laserfiche WebLink
DF-52121:C•E V5 <br /> MMF.300(A) Series, <br /> MDF-300(A) @Rre-UTUALarms <br /> ( ) <br /> Addressable Monitor Modules by Honeywell <br /> Addressab— <br /> le Devices J <br /> General <br /> Four different monitor modules are available for Fire•Lite's <br /> intelligent control panels to suit a variety of applications.Moni- <br /> tor modules are used to supervise a circuit of dry-contact input <br /> devices,such as conventional heat detectors and pull stations, <br /> or monitor and power a circuit of two-wire smoke detectors <br /> (MMF-302(A)). <br /> MMF-300(A)is a standard-sized module(typically mounts to a <br /> 4' [10.16 cm) square box) that supervises either a Style D <br /> (Class A) or Style B (Class B) circuit of dry-contact input <br /> devices. <br /> MMF-301(A)is a miniature monitor module a mere 1.3"(3.302 <br /> cm)H x 2.75"(6.985 cm)W x 0.5"(1.270 cm)D used to super- <br /> vise a Style B(Class B)circuit of dry-contact input devices.Its <br /> compact design allows the MMF-301(A) to be mounted in a <br /> single-gang box behind the device it monitors. $ <br /> MMF-302(A)is a standard-sized module used to monitor and <br /> supervise compatible two-wire,24 volt,smoke detectors on a <br /> Style D(Class A) or Style B(Class B)circuit. <br /> MDF-300(A)is a standard-sized dual monitor module used to MMF-300(A)(Type H) <br /> monitor and supervise two independent two-wire Style B <br /> (Class B) dry-contact initiating device circuits (IDCs) at two may be wired as an NFPA Style B(Class B)or Style D(Class <br /> separate,consecutive addresses in intelligent,two-wire systems. A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor <br /> LiteSpeedTm is a communication protocol developed by (provided) terminates the Style B circuit. No resistor is <br /> Fire•Lite Engineering that greatly enhances the speed of com- required for supervision of the Style D circuit. <br /> munication between analog intelligent devices. Intelligent MMF-300(A) OPERATION <br /> devices communicate in a grouped fashion. If one of the <br /> devices within the group has new information, the panel CPU Each MMF-300(A) uses one of the available module <br /> stops the group poll and concentrates on single points. The addresses on an SLC loop. It responds to regular polls from <br /> net effect is response speed greater than five times that of the control panel and reports its type and the status(open/nor- <br /> other designs.designs. mal/short)of its Initiating Device Circuit(IDC).A flashing LED <br /> indicates that the module is in communication with the control <br /> MMF-300(A) Monitor Module panel. The LED latches steady on alarm (subject to current <br /> • Built-in type identification automatically identifies this device limitations on the loop). <br /> as a monitor module to the control panel. MMF-300(A) SPECIFICATIONS <br /> • Powered directly by two-wire SLC loop.No additional power Nominal operating voltage:15 to 32 VDC. <br /> required. Maximum current draw:5.0 mA(LED on). <br /> • High noise(EMF/RFI)immunity. Average operating current: 350 NA (LED flashing), 1 com- <br /> • SEMS screws with clamping plates for ease of wiring. munication every 5 seconds,47k EOL. <br /> • Direct-dial entry of address: 01 –159 on MS-9600 series Maximum IDC wiring resistance:40 ohms. <br /> panels,01–99 on other compatible systems. EOL resistance:47K ohms. <br /> • LED flashes during normal operation and latches on steady <br /> to Indicate alarm. Temperature range:32•F to 120°F(0°C to 49°C). <br /> The MMF-300(A)Monitor Module is intended for use in intelli- Humidity range:10%to 93%noncondensing. <br /> gent,two-wire systems,where the individual address of each Dimensions 4.5' (11.43 cm) high x 4' (10.16 cm) wide x <br /> module is selected using the built-in rotary switches. It pro <br /> vides either atwo-wire or four-wire fault-tolerant Initiatin1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x <br /> g 2 125'(5.398 cm)deep box. <br /> Device Circuit(IDC)for normaly-open-contact fire alarm and <br /> supervisory devices.The module has a panel-controlled LED <br /> indicator. The MMF-300(A)can be used to replace M300(A) <br /> modules in existing systems. <br /> MMF-300(A)APPUCATIONS <br /> Use to monitor a zone of four-wire smoke detectors, manual <br /> fire alarm pull stations, waterlow devices, or other normally- <br /> open dry-contact alarm activation devices. May also be used <br /> to monitor normally-open supervisory devices with special <br /> supervisory indication at the control panel. Monitored circuit <br /> DF-52121:0.10/06/2010 Page 1 of 4 <br />