09/19/02 THU 10:26 FAX 7634796691 ER SYSTEMS IM 004 <br /> Page 6 of 7 FACTORY MUTUAL RESEARCH <br /> OB6A5AM <br /> 5.1.4 Eraguard 2000- Primer-FR is a base coat spray or roller applied to <br /> existing Approved insulated or uninsulated metal panel roofs at a minimum application rate of <br /> 0.5 gal/square (0.2 Q/m:') with a minimum 4 mil [0.004 in. (0.1 mm)] dry thickness. After a 12 to <br /> 24 hour cure Eraguard 1000 FR, White is applied In a two coat application with each coating <br /> applied at a minimum rate of 0.75 gal/square (0.3 Q/m') with a minimum 12.5 mil 10.0125 In. (0.3 <br /> mm)] dry thickness. The total dry thickness is minimum 16.5 mil [0.0165 in. (0.42 mm)]. <br /> 5.1.5 ASTM E108 Ratings <br /> 5.1.5.1 The Eraguard 1000 FR, Gray/Eraguard 1000 FR, White mee <br /> Class A ASTM E108 non-combustible deck rating at a maximum roof slope of 1 in 12 when <br /> applied aver the maximum 3 in. (76 mm) thick polyurethane spray foam shown in 5.1.1 above. <br /> 5.1.5.2 The Eraguard 2000 - Primer-FR/Eraguard 1000 FR, White <br /> combination meets Class A ASTM E108 non-combustible deck rating at a maximum roof slope <br /> of 1 in 12 when applied over an Factory Mutual'Research Approved insulated or uninsulated <br /> metal panel roof. <br /> 5.1.6 Hail Ratings -All of the above constructions meet Class 1-SH Nail Rating. <br /> 5.2 The roof cover must be installed using an Factory Mutual Research Approved <br /> perimeter flashing system. Refer to the current edition of the Factory Mutual Research Approval <br /> Guide for details. <br /> 5.3 Test results show that the above roof constructions, in and of themselves alone, <br /> would not create a need for automatic sprinkler protection. <br /> 5.4 The tested roof systems, when Installed as described above, meet the Factory <br /> Mutual Research Approval Standards and when Approval is effective, will be listed in the <br /> Factory Mutual Research Approval Guide, Roof Coverings section. <br /> 5.5 Approval is effective when the Approval Agreement is signed and received by <br /> Factory Mutual Research. <br /> 5.6 Continued Approval depends on satisfactory field experience and periodic Quality <br /> Audit Inspections. <br /> 5.7 The securement of the roof system must be enhanced at the building comers and <br /> perimeter as outlined in FM Global Property Loss Prevention Data Sheets 1-28 for roof decks <br /> and 1-29 for above deck components. <br /> VI MARKING <br /> 6.1 The manufacturer shall mark each packing container(pail or drum)with the <br /> manufacturer's name and product trade name. In addition, the container must be marked with <br /> the Factory Mutual Research Approval Mark and the words, "Subject to the conditions of <br /> Approval as a protective roof coating for use in Class 1 roof construction as described in the <br /> current edition of the Factory Mutual Research Approval Guide." <br /> 6.2 Markings denoting Factory Mutual Research Approval shall by applied by the <br /> manufacturer only within and on the premises of manufacturing locations that are under the <br /> Factory Mutual Research Facilities and Procedures Audit Program. <br />