2015 - 01168 - plumbing
Orono
>
Property Files
>
Street Address
>
W
>
Wayzata Boulevard West
>
2160 Wayzata Boulevard West - 34-118-23-21-0002
>
Permits/Inspections
>
2015 - 01168 - plumbing
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:54:04 PM
Creation date
1/13/2020 10:43:35 AM
Metadata
Fields
Template:
x Address Old
House Number
2160
Street Name
Wayzata
Street Type
Boulevard
Street Direction
West
Address
2160 Wayzata Boulevard West
Document Type
Permits/Inspections
PIN
3411823210002
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Orono Station West <br /> Plumbing <br /> Plan No.PLB 1508-00306 <br /> Page 2 <br /> September 9,2015 <br /> d. Cappuccino machine. <br /> e. Slushie Machine. <br /> Each fixture or piece of equipment must be protected individually. A single backflow preventer may not <br /> serve more than one piece of equipment. <br /> The Watts.Model SD3 is an example of a stainless steel double-cheek valve with an intermediate <br /> atmospheric vent(DC'ViAV)listed to ASSE Standard 1022.which is approved for the installations listed <br /> above. <br /> Please note that the Watts.Model 90.(DCViAV).listed to ASSE 1012(approved for the noncarbonated <br /> installations listed above).does not comply with the January 4.2014.Reduction in Lead Drinking Water Act. <br /> The Watts.Model 9BD does not appear to be listed to ASSE Standard 1012 or 1022 <br /> 3 Based on the Minnesota Plumbing Code.a plumbing system includes all potable water supplies.distribution <br /> pipes.and potable water treatment and using equipment(see Minnesota Rules,part 4715.0100.subpart 81). <br /> All portions of the water treatment and water distribution systems up to the beverage dispensers must be <br /> installed by a licensed and bonded plumber. <br /> 4. Indirect waste pipes from appliances,devices,or equipment not regularly classed as plumbing fixtures,but <br /> which are equipped with drainage outlets,must he trapped.but the traps need not be vented. The waste pipe <br /> must be at least 3 4 inches in size.but not less than the size of the outlet or tail piece of the equipment served <br /> (see Minnesota Rules.part 4715.15101. <br /> 5. A full-way valve must be provided on the cold water supply line to the water heater(see Minnesota Rules. <br /> part 4715.1800). <br /> 6. Tankless-and instantaneous-type water heaters require pressure relief valves only. instantaneous electric <br /> water heaters that have UL approval for use without a relief vale,and that have space containing the heating <br /> element of less than 3 inches in diameter.may be installed without a pressure relief valve(see Minnesota <br /> Rules,part 4715.2230). <br /> 7. A water heater with a tank capacity up to 6 gallons may be concealed in a ceiling tithe water heater has a <br /> corrosion resistant overflow pan with 4-inch minimum side walls. The outlet may not be smaller than the <br /> water heater supply line and must continue full-size to a point of safe disposal below the ceiling. Access to <br /> the water heater must not require tools see Minnesota Rules.pan 4715.2240). The relief rah pipe should <br /> be routed independently to a point of'safe disposal below the ceiling. <br /> 8. Water closets in public bathrooms must have elongated bowls with open-front seats(see Minnesota Rules. <br /> part 4715.1420). <br /> 9. The horizontal distance between cleanouts may not exceed 50 feet for pipe 3 inches or less in size,and not <br /> over 100 feet for pipe 4 inches and greater in size(see Minnesota Rules,part 4715.1010). <br /> 10. It is recommended that a cleanout be provided where new waste and vent piping connects with existing <br /> plumbing to facilitate required testing of the new installation. <br />