Laserfiche WebLink
Ste)rj, /1r1Lr A.f.3,3 tu�v35 -1 . 3 (. <br /> building on a single piece of property. In assemblies in accordance with Section <br /> addition, the agreement must state that no 714.2.3.2 and shall be self-closing or <br /> individual building or property owner may automatic closing by smoke detection. <br /> modify any portion of the building in any way <br /> that would not be in compliance with the Subp. 2. Section 707.14.1. IBC Section <br /> Minnesota State Building Code. 707.14.1 is amended to read as follows: <br /> 1305.0600 Repealed 707.14.1 Elevator lobby. Elevators opening <br /> into fire resistance-rated corridor,as required <br /> 1305.0700 Repealed by Section 1004.3.2.1 shall be provided with <br /> an elevator lobby at each floor containing <br /> 1305.0704 SECTION 704,EXTERIOR such a corridor. The lobby shall completely <br /> WALLS. separate the elevators from the corridor by <br /> fire barriers and the required opening <br /> IBC Section 704.2.3 is amended to read as protection. Elevator lobbies shall have at <br /> follows: least one means of egress complying with <br /> Chapter 10 and other provisions within this <br /> 704.2.3 Combustible projections. code. Nps,- AA?1/OA. <br /> Combustible projections located where (3e CA--;SJ? o 0 Li•3.z.1 Exce-p n o..0 Y <br /> openings are not permitted or where Exceptions: Lon-p cP. <br /> protection of openings is required shall be of <br /> at least 1-hour fire-resistance-rated 1. In office buildings, separations are not <br /> construction, Type IV construction or as required from a street floor elevator lobby <br /> required by Section 1406.3. Openings provided the entire street floor is equipped <br /> necessary for attic ventilation where with an automatic sprinkler system in <br /> protection of openings is required shall not be accordance with Section 903.3.1.1. <br /> located in eave overhangs unless the <br /> ventilation openings are protected or the attic 2. Elevators not required to be located in a <br /> is protected by an automatic fire suppression shaft in accordance with Section 707.2. 0.0 <br /> system. There shall be no openings for attic <br /> ventilation in eave overhangs where openings 3. Where additional fire or smoke rated <br /> are not permitted. doors or other assemblies meeting the r,! <br /> requirements of 714.2.3 are provided in <br /> Exception: Type V construction shall be accordance with Section 3002.6. <br /> allowed for R-3 occupancies, as applicable in <br /> Section 101.2. 4. In other than Groups I-2 and I-3, and <br /> buildings more than four stories above the <br /> 1305.0707 SECTION 707,SHAFT lowest level of fire department vehicle access, <br /> ENCLOSURES. lobby separation is not required where the <br /> building, including the lobby and corridors <br /> Subpart 1. Section 707.7. IBC Section leading to the lobby, is protected by an <br /> 707.7 is amended to read as follows: automatic sprinkler system installed <br /> throughout in accordance with Section <br /> 707.7 Openings. Openings in a shaft <br /> l ) enclosure shall be protected in accordance 903.3.1.1 or 903.3.1.2. <br /> with Section 714 as required for fire barriers 1305.0714 SECTION 714,OPENING <br /> and listed in Table 714.2. Such openings PROTECTIVES. <br /> shall restrict the movement of smoke through <br /> openings using smoke and draft control IBC Section 714.2.3 is amended to read as <br /> 207 <br />