My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Fire Alarm System
Orono
>
Property Files
>
Street Address
>
W
>
Wayzata Boulevard West
>
0200 Wayzata Boulevard West - 36-118-23-43-0001
>
Misc
>
Fire Alarm System
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:05:14 PM
Creation date
12/30/2019 11:42:59 AM
Metadata
Fields
Template:
x Address Old
House Number
200
Street Name
Wayzata
Street Type
Boulevard
Street Direction
West
Address
200 Wayzata Boulevard West
Document Type
Misc
PIN
3611823430001
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ste)rj, /1r1Lr A.f.3,3 tu�v35 -1 . 3 (. <br /> building on a single piece of property. In assemblies in accordance with Section <br /> addition, the agreement must state that no 714.2.3.2 and shall be self-closing or <br /> individual building or property owner may automatic closing by smoke detection. <br /> modify any portion of the building in any way <br /> that would not be in compliance with the Subp. 2. Section 707.14.1. IBC Section <br /> Minnesota State Building Code. 707.14.1 is amended to read as follows: <br /> 1305.0600 Repealed 707.14.1 Elevator lobby. Elevators opening <br /> into fire resistance-rated corridor,as required <br /> 1305.0700 Repealed by Section 1004.3.2.1 shall be provided with <br /> an elevator lobby at each floor containing <br /> 1305.0704 SECTION 704,EXTERIOR such a corridor. The lobby shall completely <br /> WALLS. separate the elevators from the corridor by <br /> fire barriers and the required opening <br /> IBC Section 704.2.3 is amended to read as protection. Elevator lobbies shall have at <br /> follows: least one means of egress complying with <br /> Chapter 10 and other provisions within this <br /> 704.2.3 Combustible projections. code. Nps,- AA?1/OA. <br /> Combustible projections located where (3e CA--;SJ? o 0 Li•3.z.1 Exce-p n o..0 Y <br /> openings are not permitted or where Exceptions: Lon-p cP. <br /> protection of openings is required shall be of <br /> at least 1-hour fire-resistance-rated 1. In office buildings, separations are not <br /> construction, Type IV construction or as required from a street floor elevator lobby <br /> required by Section 1406.3. Openings provided the entire street floor is equipped <br /> necessary for attic ventilation where with an automatic sprinkler system in <br /> protection of openings is required shall not be accordance with Section 903.3.1.1. <br /> located in eave overhangs unless the <br /> ventilation openings are protected or the attic 2. Elevators not required to be located in a <br /> is protected by an automatic fire suppression shaft in accordance with Section 707.2. 0.0 <br /> system. There shall be no openings for attic <br /> ventilation in eave overhangs where openings 3. Where additional fire or smoke rated <br /> are not permitted. doors or other assemblies meeting the r,! <br /> requirements of 714.2.3 are provided in <br /> Exception: Type V construction shall be accordance with Section 3002.6. <br /> allowed for R-3 occupancies, as applicable in <br /> Section 101.2. 4. In other than Groups I-2 and I-3, and <br /> buildings more than four stories above the <br /> 1305.0707 SECTION 707,SHAFT lowest level of fire department vehicle access, <br /> ENCLOSURES. lobby separation is not required where the <br /> building, including the lobby and corridors <br /> Subpart 1. Section 707.7. IBC Section leading to the lobby, is protected by an <br /> 707.7 is amended to read as follows: automatic sprinkler system installed <br /> throughout in accordance with Section <br /> 707.7 Openings. Openings in a shaft <br /> l ) enclosure shall be protected in accordance 903.3.1.1 or 903.3.1.2. <br /> with Section 714 as required for fire barriers 1305.0714 SECTION 714,OPENING <br /> and listed in Table 714.2. Such openings PROTECTIVES. <br /> shall restrict the movement of smoke through <br /> openings using smoke and draft control IBC Section 714.2.3 is amended to read as <br /> 207 <br />
The URL can be used to link to this page
Your browser does not support the video tag.