My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Fire Alarm System
Orono
>
Property Files
>
Street Address
>
W
>
Wayzata Boulevard West
>
0200 Wayzata Boulevard West - 36-118-23-43-0001
>
Misc
>
Fire Alarm System
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:05:14 PM
Creation date
12/30/2019 11:42:59 AM
Metadata
Fields
Template:
x Address Old
House Number
200
Street Name
Wayzata
Street Type
Boulevard
Street Direction
West
Address
200 Wayzata Boulevard West
Document Type
Misc
PIN
3611823430001
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ESR-1136 <br /> EREPORT"' Issued March 1, 2004 <br /> This report is subject to re-examination in one year. <br /> ICC Evaluation Service, Inc. Business/Regional Office•5360 Workman Mill Road,Whittier,California 90601 •(562)699-0543 <br /> Regional Office■900 Montclair Road,Suite A,Birmingham,Alabama 35213 •(205)599-9800 <br /> www.icc-es.org Regional Office•4051 West Flossmoor Road,Country Club Hits,Illinois 60478■(708)799-2305 <br /> DIVISION:07—THERMAL AND MOISTURE PROTECTION The film protects the elevator opening from vertical smoke <br /> Section:07870—Smoke Containment Barriers migration by creating a tight-fitting smoke and draft control <br /> barrier. The system is connected to the smoke detection <br /> DIVISION:08—DOORS AND WINDOWS system located in the elevator lobby which initiates <br /> Section:08300—Specialty Doors deployment within 10 seconds of the smoke detector's going <br /> into alarm. A cabling system allows the film to unwind. <br /> REPORT HOLDER: Flexible magnetic strips,on the vertical sides of the film,seal <br /> the film to the elevator door frame or the auxiliary rails. The <br /> SMOKE GUARD®CORPORATION system is capable of sensing an object in its path and will not <br /> 11420 EXECUTIVE DRIVE fully unroll until the object is removed. Film-mounted rewind <br /> BOISE,IDAHO 83713 switches reset the system.For the Model 600 a separate wall <br /> switch will also rewind the system. <br /> (208)383-3789 <br /> www.smokeguard.com In the event that a® elevator occupant encounters a <br /> info(a)smokequard.com deployed Smoke Guard®System,a rewind switch located on <br /> both sides of the film can be activated to allow the occupant <br /> EVALUATION SUBJECT: to exit from the elevator.The film will redeploy after egress.In <br /> the event of loss of power,a force of less than 15 foot-pounds <br /> (66 N) is required at the film boundary to push the magnets <br /> SMOKE GUARD® SYSTEM—MODELS 200, 400 AND 600 away from the hoistway frame.The systems have air leakage <br /> SMOKE CONTAINMENT SYSTEMS ratings that do not exceed 3.0 cfm per square foot of opening <br /> at 0.1 inch water pressure(25 Pa)difference at both ambient <br /> 1.0 EVALUATION SCOPE and elevated temperatures. See Figure 1 of this report for a <br /> Compliance with the following codes: typical installation. <br /> • 2000 International Building Code®(IBC) 3.2 Components: <br /> • 2002 Accumulative Supplement to the International 3.2.1 Film: The film is a minimum 1.0-mil-thick [0.01 inch <br /> Codes T"" (0.025 mm)]polyimide plastic sheet with a transparent orange <br /> color.A minimum 100 denier filament yarn is factory-adhered <br /> • BOCA®National Building Code/1999(BNBC) to the film as reinforcement. <br /> • 1999 Standard Building Code®(SBC) 3.2.2 Magnets: Strip magnets, a minimum of 21/2 inches <br /> • 1997 Uniform Building Code" (UBC) wide by 1/8 inch thick(65 mm by 3.2 mm),are attached to the <br /> vertical edges of the film with continuous beads of silicone <br /> Properties evaluated: sealant. The strips utilize a multipole flexible magnet <br /> Smoke containment consisting of energized ferrite in a nitrile rubber binder which <br /> 2.0 USES exerts a minimum force of 1.4 MGOe. <br /> The Smoke Guard® System is a rolling gasketing smoke 3.2.3 Motor:The motors are DC units rated at a minimum <br /> containment system used in conjunction with a fire- of 25 inch-pounds (2.8 N-m) at 100 rpm. The units are <br /> resistance-rated elevator hoistway door and frame assembly powered by 120 volt AC power. The Model 200 and 400 <br /> to provide a smoke and draft control assembly. The system systems use a 90V-DC gear motor and a 90V DC clutch,with <br /> is installed over elevator openings that open into a fire- a viscous governor connected to the drive system.The Model <br /> resistance-rated corridor, and is intended to be used as an 600 unit uses a 12V-DC gear motor that is connected to the <br /> alternative to the requirement for a separated elevator lobby drive pulley. <br /> in the applicable code. 3.2.4 Electro/Electronic Drive Control System:The drive <br /> 3.0 DESCRIPTION control system, which controls the deployment and rewind <br /> functions of the system, is connected to an independent <br /> 3.1 General: 120V-AC power source and the auxiliary contacts of the <br /> elevator lobby smoke detector. The Model 600 is equipped <br /> The Smoke Guard® System consists of a reinforced <br /> transparent film designed to unroll from a housing unit with a 12V-DC back-up battery and charger. The electrical <br /> positioned above the elevator opening, down along the control release mechanisms shall conform to UL Standard <br /> existing elevator frame or auxiliary rails to cover the elevator 864. <br /> opening in the event of a fire. Auxiliary rails are used if the 3.2.5 Sealant:The sealant shall be a low-modulus,silicone <br /> elevator frame is nonferrous,beveled,painted,irregular,or if sealant, complying with ASTM C 920, Type S, Grade NS, <br /> the look of rails is desired. Class 25, Use T, NT, M,G,A and O. <br /> Es REPORTS"are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed as an endorsement of the subject <br /> of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,Inc.,express or implied,as to any Ending or other matter in this report,or as to any <br /> product covered by the report. <br /> Copyright©2004 Page 1 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.