My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Fire Alarm System
Orono
>
Property Files
>
Street Address
>
W
>
Wayzata Boulevard West
>
0200 Wayzata Boulevard West - 36-118-23-43-0001
>
Misc
>
Fire Alarm System
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:05:14 PM
Creation date
12/30/2019 11:42:59 AM
Metadata
Fields
Template:
x Address Old
House Number
200
Street Name
Wayzata
Street Type
Boulevard
Street Direction
West
Address
200 Wayzata Boulevard West
Document Type
Misc
PIN
3611823430001
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MEANS OF EGRESS 1004.3.1.1 —1004.3.2.2 <br /> inches (178 mm). Doors in any position shall not 1004.3.1.3.3 Table and seating aisle accessway <br /> reduce the required width by more than one-half.Other length. The length of travel along the aisle access- <br /> nonstructural projections such as trim and similar dec- way shall not exceed 30 feet (9144 mm) from any <br /> orative features are permitted to project into the seat to the point where a person has a choice of two <br /> required width 1.5 inches (38 mm)from each side. or more paths of egress travel to separate exits. <br /> 1004.3.1.1 Public areas Group B and M. In public -// 1004.3.2 Corridors. Corridors shall comply with <br /> areas of Group B and M occupancies, the minimum b Sections 1004.3.2.1 through 1004.3.2.5. <br /> clear aisle width shall be 36 inches (914 mm) where <br /> seats, tables, furnishings, displays and similar fixtures 1004.3.2.1 Construction.Corridors shall be fire-resis- <br /> or equipment are placed on only one side of the aisle tance rated in accordance with Table 1004.3.2.1. The <br /> and 44 inches(1118 mm)where such fixtures or equip- corridor walls required to be fire-resistance-rated shall <br /> ment are placed on both sides of the aisle. comply with Section 708 for fire partitions. <br /> 1004.3.1.2 Nonpublic areas. In nonpublic areas, aisle Exceptions: <br /> widths shall be a minimum of 36 inches(914 mm). 1. A fire-resistance rating is not required for cor- <br /> Exception: Nonpublic aisles serving less than 50 ridors in an occupancy in Gaup where each <br /> people,and not required to be accessible by Chapter room that is used for instruction has at least <br /> 11 need not exceed 28 inches (711 mm)in width. one door directly to the exterior and rooms for <br /> assembly purposes have at least one-half of <br /> 1004.3.1.3 Seating at tables. Where seating is located the required means of egress doors opening <br /> at a table or counter and is adjacent to an aisle or aisle directly to the exterior. Exterior doors speci <br /> accessway,the measurement of required clear width of feed in this exception are required to be at <br /> the aisle or aisle accessway, shall be made to a line 19 ground level. <br /> inches(483 mm)away from and parallel to the edge of 2. A fire-resistance rating is not required for cor- <br /> the table or counter. The 19-inch (483 mm) distance ridors contained within a dwelling unit or a <br /> shall be measured perpendicular to the side of the table guestroom in an occupancy in Group R. <br /> or counter.In the case of other side boundaries for aisle 3. A fire-resistance rating is not required for cor- <br /> or aisle accessways, the clear width shall be measured ridors in open parking garages. <br /> to walls, edges of seating and tread edges, except that <br /> 1X-4. A fire-resistance rating is not required for cor- <br /> handrail projections are permitted. ridors in an occupancy in Group B which is a <br /> space requiring only a single mead of egrressr <br /> Exception: Where tables or counters are served by <br /> complying with Section 1004.2.1. <br /> fixed seats,the width of the aisle accessway shall be a ccort.di -Fo ton-eL�, <br /> measured from the back of the seat. 1004.3.2.2 Corridor width. The minimum corridor <br /> width shall be as determined in Section 1003.2.3, but <br /> 1004.3.1.3.1 Aisle accessway for tables and seat- not less than 44 inches (1118 mm). <br /> ing.Aisle accessways serving arrangements of seat- <br /> ing at tables or counters shall have sufficient clear Exceptions: <br /> width to conform to the capacity requirements of 1. Twenty-four inches (610 mm)—For access to <br /> 1003.2.3 but shall not have less than the appropriate and utilization of electrical, mechanical, or <br /> minimum clear width specified in Section plumbing systems or equipment. <br /> 1004.3.1.2. 2. Thirty-six inches (914 mm)—With a required <br /> occupant capacity of 50 or less. <br /> 1004.3.1.3.2 Table and seating accessway width. <br /> Aisle accessways shall provide a minimum of 12 3. Thirty-six inches (914 mm)—Within a <br /> inches (305 mm) of width plus 0.5 inch (12.7 mm) dwelling unit. <br /> of width for each additional 1 foot (305 mm), or 4. Seventy-two inches (1829 mm)—in Group E <br /> fraction thereof, beyond 12 feet(3658 mm) of aisle with a corridor having a required capacity of <br /> accessway length measured from the center of the 100 or more. <br /> seat farthest from an aisle. 5. Seventy-two inches (1829 mm)—In corridors <br /> serving surgical Group I, health-care centers <br /> Exception: Portions of an aisle accessway hay- for ambulatory patients receiving outpatient <br /> ing a length not exceeding 6 feet(1829 mm) and medical care, which causes the patient to be <br /> used by a total of not more than four persons. not capable of self-preservation. <br /> 2000 INTERNATIONAL BUILDING CODE® 233 <br />
The URL can be used to link to this page
Your browser does not support the video tag.