MEANS OF EGRESS 1004.3.1.1 —1004.3.2.2 <br /> inches (178 mm). Doors in any position shall not 1004.3.1.3.3 Table and seating aisle accessway <br /> reduce the required width by more than one-half.Other length. The length of travel along the aisle access- <br /> nonstructural projections such as trim and similar dec- way shall not exceed 30 feet (9144 mm) from any <br /> orative features are permitted to project into the seat to the point where a person has a choice of two <br /> required width 1.5 inches (38 mm)from each side. or more paths of egress travel to separate exits. <br /> 1004.3.1.1 Public areas Group B and M. In public -// 1004.3.2 Corridors. Corridors shall comply with <br /> areas of Group B and M occupancies, the minimum b Sections 1004.3.2.1 through 1004.3.2.5. <br /> clear aisle width shall be 36 inches (914 mm) where <br /> seats, tables, furnishings, displays and similar fixtures 1004.3.2.1 Construction.Corridors shall be fire-resis- <br /> or equipment are placed on only one side of the aisle tance rated in accordance with Table 1004.3.2.1. The <br /> and 44 inches(1118 mm)where such fixtures or equip- corridor walls required to be fire-resistance-rated shall <br /> ment are placed on both sides of the aisle. comply with Section 708 for fire partitions. <br /> 1004.3.1.2 Nonpublic areas. In nonpublic areas, aisle Exceptions: <br /> widths shall be a minimum of 36 inches(914 mm). 1. A fire-resistance rating is not required for cor- <br /> Exception: Nonpublic aisles serving less than 50 ridors in an occupancy in Gaup where each <br /> people,and not required to be accessible by Chapter room that is used for instruction has at least <br /> 11 need not exceed 28 inches (711 mm)in width. one door directly to the exterior and rooms for <br /> assembly purposes have at least one-half of <br /> 1004.3.1.3 Seating at tables. Where seating is located the required means of egress doors opening <br /> at a table or counter and is adjacent to an aisle or aisle directly to the exterior. Exterior doors speci <br /> accessway,the measurement of required clear width of feed in this exception are required to be at <br /> the aisle or aisle accessway, shall be made to a line 19 ground level. <br /> inches(483 mm)away from and parallel to the edge of 2. A fire-resistance rating is not required for cor- <br /> the table or counter. The 19-inch (483 mm) distance ridors contained within a dwelling unit or a <br /> shall be measured perpendicular to the side of the table guestroom in an occupancy in Group R. <br /> or counter.In the case of other side boundaries for aisle 3. A fire-resistance rating is not required for cor- <br /> or aisle accessways, the clear width shall be measured ridors in open parking garages. <br /> to walls, edges of seating and tread edges, except that <br /> 1X-4. A fire-resistance rating is not required for cor- <br /> handrail projections are permitted. ridors in an occupancy in Group B which is a <br /> space requiring only a single mead of egrressr <br /> Exception: Where tables or counters are served by <br /> complying with Section 1004.2.1. <br /> fixed seats,the width of the aisle accessway shall be a ccort.di -Fo ton-eL�, <br /> measured from the back of the seat. 1004.3.2.2 Corridor width. The minimum corridor <br /> width shall be as determined in Section 1003.2.3, but <br /> 1004.3.1.3.1 Aisle accessway for tables and seat- not less than 44 inches (1118 mm). <br /> ing.Aisle accessways serving arrangements of seat- <br /> ing at tables or counters shall have sufficient clear Exceptions: <br /> width to conform to the capacity requirements of 1. Twenty-four inches (610 mm)—For access to <br /> 1003.2.3 but shall not have less than the appropriate and utilization of electrical, mechanical, or <br /> minimum clear width specified in Section plumbing systems or equipment. <br /> 1004.3.1.2. 2. Thirty-six inches (914 mm)—With a required <br /> occupant capacity of 50 or less. <br /> 1004.3.1.3.2 Table and seating accessway width. <br /> Aisle accessways shall provide a minimum of 12 3. Thirty-six inches (914 mm)—Within a <br /> inches (305 mm) of width plus 0.5 inch (12.7 mm) dwelling unit. <br /> of width for each additional 1 foot (305 mm), or 4. Seventy-two inches (1829 mm)—in Group E <br /> fraction thereof, beyond 12 feet(3658 mm) of aisle with a corridor having a required capacity of <br /> accessway length measured from the center of the 100 or more. <br /> seat farthest from an aisle. 5. Seventy-two inches (1829 mm)—In corridors <br /> serving surgical Group I, health-care centers <br /> Exception: Portions of an aisle accessway hay- for ambulatory patients receiving outpatient <br /> ing a length not exceeding 6 feet(1829 mm) and medical care, which causes the patient to be <br /> used by a total of not more than four persons. not capable of self-preservation. <br /> 2000 INTERNATIONAL BUILDING CODE® 233 <br />