2008-P12228 (00020) - new septic
Orono
>
Property Files
>
Street Address
>
W
>
Watertown Road
>
3940 Watertown Road - 32-118-23-32-0001
>
Septic
>
2008-P12228 (00020) - new septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:40:30 PM
Creation date
11/4/2019 1:48:52 PM
Metadata
Fields
Template:
x Address Old
House Number
3940
Street Name
Watertown
Street Type
Road
Address
3940 Watertown Road
Document Type
Septic
PIN
3211823320001
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The soils at a depth of 12" have a percolation rate of 8.3 mpi. <br /> A pumping chamber will need to be installed to lift the effluent to the treatment area. <br /> The power supply and switches must be located outside the manhole and pumping <br /> chamber in a weather proof enclosure. A warning device must be installed with a light <br /> and sound device, this is in case of a pump failure. <br /> The manifold and supply line pipe must have back drainage to the pumping chamber. <br /> The distribution pipes shall have their ends capped. Be sure the rock and sand fill <br /> material are clean. The sod layer below the entire mounded area must be turned over, <br /> just break up the sod, be sure not to over work. <br /> All neighboring wells are located greater than 100' away from the proposed treatment <br /> area. <br /> Keep all heavy equipment off of the proposed treatment area before and after <br /> construction. The treatment area should be marked off before construction. This <br /> Design is not valid &the system will need to be relocated if failure to protect the areas <br /> proposed for On-Site Sewage Treatment occurs. <br /> With proper installation and maintenance, this system should have no problem in <br /> treating septic effluent effectively. <br /> Nothing other than human waste, toilet tissue, laundry, showers, water softener etc. <br /> should be disposed of into the septic tanks. Recommend Iron filters be diverted out of <br /> the system. Recommend to divert the water softner also if the iron filter is diverted. <br /> Garbage disposals are not recommended, due to adding more solids &fine solids <br /> passing through to the system. Excessive amounts of soaps, antibacterial soaps, <br /> cleaning agents, shower cleaners used every shower&chlorine agents may kill the <br /> bacteria needed to treat septic effluent. Additives are not recommended. Recommend <br /> to pump & clean your tanks through the manhole by a certified pumper every 2 years. <br /> Check with your pumper to set up a schedule. Recommend laundering be limited to 3 <br /> to 4 loads per day. <br /> <::�;L 3 . ��- <br /> Steven B. Schirmers <br /> 2 <br />