Laserfiche WebLink
OSTP Pressure Distribution <br /> UNIVERSITY <br /> Minnesota Pollution Design Worksheet ` <br /> Control Agency OF MINNESOTA ,`. „ <br /> 12. Select Type of Manifold Connection (End or Center): E End ❑ Center <br /> 13. Select Lateral Diameter: 2.00 in Table II <br /> Volume of Liquid in <br /> 14. Volume of Liquid Per Foot of Distribution Piping: 0.170 Gallons/ft Pipe <br /> 15. Volume of Distribution Piping = Pipe Liquid <br /> Diameter Per Foot <br /> _[Number of Perforated Laterals (Line 1)X Length of Laterals (Line 4)X (inches) (Gallons) <br /> (Volume of Liquid Per Foot of Distribution Piping(Line 14)] 1 0.045 <br /> 3 X 61 ft X 0.170 gal/ft = 31.1 Gallons 1.25 0.078 <br /> 1.5 0.110 <br /> 16. Minimum Dose=Volume of Distribution Piping(Line 15)X 4 2 0.170 <br /> 3 0.380 <br /> 31.1 gals X 4 = 124.4 Gallons 4 0.661 <br /> manifold pipet _-Cleanouu -- -- <br /> pipe from pump ;' Manifold pipe` J <br /> a► J <br /> � --- <br /> clean outs 100 e ' V <br /> `=./ Alternate location <br /> rte �. No,,, pipe from pump <br /> alternate location <br /> of pipe from pump , ... <br /> Pi a from ump <br /> Comments/Special Design Considerations: <br />