2017 MPCA Soil and Percolation Testing
Orono
>
Property Files
>
Street Address
>
O
>
Old Crystal Bay Road South
>
0425 Old Crystal Bay Road South - 04-117-23-31-0001
>
Septic
>
2017 MPCA Soil and Percolation Testing
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:12:03 PM
Creation date
9/27/2019 10:46:20 AM
Metadata
Fields
Template:
x Address Old
Address
0425 Old Crystal Bay Rd S
Document Type
Septic
PIN
0411723310001
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Installer Summary <br /> 2250 gallon Septic tank (minimum) Tank options: none <br /> aux larger lanK wnn muuIpie comp/lanKS <br /> 1300 gallon Dose tank (minimum) at 25.49 gpi <br /> 36 JGPM F 32 ft. of head, Pump required <br /> 8.6 inch swing on Demand float which translates to roughly 5.3 inches of float tether length <br /> if time dosing is required —F-6-—1minutes ON time ti hours OFF time <br /> 21 inches from bottom of tank to"pump ON"float, or 12 inches to"timer ON"float <br /> 24 inches from bottom of tank to"Hi Level Alarm"or =inches to"Hi level alarm"if time dosed <br /> 185 ft. of r 2.0 inch supply tine with end feed manifold connection <br /> (Tip: "top feed"manifold to control drainback) <br /> 18 inch, or 1.5 ft. Sand Lift Mound <br /> 10.0 ft. wide by 63.0 ft. long Rock bed <br /> 3 laterals 2.00 inch diameter 61.0 ft. long 3.0 ft. lateral spacing <br /> 7/32 inch perfs 3.0 ft. perforation spacing <br /> No Effluent filter ti alarm <br /> 3 clean out a valve box assemblies <br /> 27.0 ft.Total sand ABSORPTION width (minimum) <br /> 0.0 ft. upslope and sideslope (sand beyond rockbed, minimum) <br /> 17.0 ft. Downslope (sand beyond rockbed, minimum) <br /> Specific slope ratios give BERM widths (topsoil beyond rockbed)of: <br /> 4:1 upslope ratio12 ft. upslope berm <br /> 4:1 sideslope 16 ft. sideslope berms <br /> 4:1 downstope 21 ft. downslope berm <br /> 4" inspection pipe <br /> 18" cover on top <br /> U slo berm 12 Downslope berm 21 <br /> 12" cover on sides <br /> (6"loamy cap&6"topsoil) <br /> 1.5 Clear,sand lift <br /> 1.5 Depth to .uniting <br /> Absorption Width z7.o Y <br /> Note: <br /> For 0 to 1%slopes, Absorption Width is measured from the Bedequally in both directions. <br /> For slopes >1%, Absorption Width is measured downhill from the upslope edge of the Bed. <br /> Rock Bed: 21.0 yd or*1.4= 29 ton 6 inches under pipe <br /> Mound Sand: 192 yd or*1.4= 269 ton calculation based on 3:1/4:1 slope from top of rockbe, <br /> Loamy Cap: 79 yd or*1.4= 111 ton 6"deep <br /> Topsoil: 91 yd or*1.4= 127 ton 6"deep <br />