My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1997-009348 - new septic system
Orono
>
Property Files
>
Street Address
>
T
>
Truffula Trail
>
125 Truffula Trail - 33-118-23-44-0041
>
Septic
>
1997-009348 - new septic system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:53:17 PM
Creation date
7/1/2019 10:24:02 AM
Metadata
Fields
Template:
x Address Old
House Number
125
Street Name
Truffula
Street Type
Trail
Address
125 Truffula Trail
Document Type
Septic
PIN
3311823440041
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0cib'5 E)I C;:,tIn <br /> T , <br /> R K 0 Homebuilders Inc . 12/19/96 <br /> 3134 130th Ave. N.W. <br /> coon Rapids , T.Ann. <br /> .lob Site; Lot 7 Blk 1 Meadow -Wood Addition, Orono, Yinn. <br /> Percolation teats and soil boiling were done on this lot in July of 1993 <br /> and at that time it was determine that there was two sites that are <br /> suitable to locate mound systems on. <br /> See the report dated8/9/96 fox' the details. <br /> ed in the spring These sites should be rechecked p g to see if the percolation <br /> h <br /> rates are the same, percolation tests aan not be accurately done at th1,s <br /> time due to the winter conditions. <br /> However the land conditions are the same as was encounter in 1993 <br /> ( no fill was added or excavtion occured on the proposed sites ) therefore <br /> It can be assumed that the same percolation rates exist. <br /> Borings were done and mmottled. soil was found at 18 inches , this is the <br /> same level that was found in 1993• <br /> Therefore at this time we will use the same percolation rates to size <br /> out the mound system at this time, however future perc tests will be <br /> done in the spring ( prior to installation) to verify this sizing <br /> factor. <br /> The ave. perc. rate in the primary site was 39.3 min/in. and. the depth <br /> to n,ottl'd soil was at 18-24 inches. <br /> The size of mound system needed fox' a 4 bedroom home 4-based-en <br /> ( based on 600 gal/day daily water useage and a perc . rate range of 4 <br /> 46-60 min/in. the sizing factors ) would be the following size; <br /> OVERALL SIZE 352E SQ.FT. <br /> Tjpslope Length---79 ft. Downslope Length--93 ft. Width--41 ft. <br /> Rock Bed Size---550 sq. ft. Width--10 ft. Length--55 ft. <br /> Amount of materials needed ; <br /> Sand---- 230 yds. 325 tons Ave. Depth--1 . 7 ft. <br /> Rock-- 21 yds. 30 tons -1 . 0 ft. <br /> Sandy Loam 40 yds --1 . 0 ft. <br /> Topsoil---100 yds. ---9 inches <br /> The above amounts could vary by plus or minus- 10 . <br /> This mound must be pressurized therefore -'a pump tank. and a pump is needed ; <br /> Size of pump tank--1000 gallon <br /> Size of pump-- 40 g.p.m(must overcome at leastl.$,' ft. head press. ) <br /> Pumping Rate--:i73 gal/circle( 4 cycles/day) <br /> An alarm system must be installed in the house to indicate pump failure <br /> this must be both a sound and a light alarm system. <br /> SII <br /> *x1t65 Or �' <br />
The URL can be used to link to this page
Your browser does not support the video tag.