Laserfiche WebLink
RIGHT-J BUILDING ANALYSIS REPORT <br /> 0 Entire House <br /> Goodin Company Job: H060919 DIESEN <br /> 09-19-06 <br /> 285 Como Ave.,St.Paul,MN 55103-1862 Phone:651-489-8831 Fax:651-489-8837 Email:john.alberg@goodinco.com Web:www.goodinco.com <br /> Project • • <br /> For: SCOTT UNDERWOOD <br /> Design Information <br /> Htg Clg Infiltration <br /> Outside db(°F) -11 88 Method Simplified <br /> Inside db(°F) 70 75 Construction quality Average <br /> Design TD(°F) 81 13 Fireplaces 0 <br /> Daily range - M <br /> Inside humidity(%) - 50 <br /> Moisture difference(gr/Ib) - 22 <br /> Heating <br /> W <br /> Component Btuh/ft2 Btuh %of load <br /> Walls 4.8 12406 24.4 <br /> Windows 32.3 9760 19.2 <br /> Doors 15.4 646 1.3 <br /> Ceilings 1.9 2906 5.7 <br /> Floors 4.7 4567 9.0 vvhft- <br /> Infiltration 59.5 20473 40.3 <br /> Ducts 0 0.0 lk <br /> Total 50759 100.0 <br /> Component Btuh/ft2 Btuh % of load wail <br /> Walls 0.7 1876 7.6 <br /> Windows 30.6 9241 37.5 <br /> IM-1 Geiro <br /> Doors 3.2 132 0.5 <br /> Ceilings 0.9 1328 5.4 WI-' ._ <br /> Floors 0.0 0 0.0 <br /> Infiltration 5.5 1878 7.6 <br /> Ducts 0 0.0 <br /> Internal gains 10200 41.4 °18W.5iqa �lvaiw <br /> Total 24655 100.0 <br /> Cooling at 88% SHR=2.2 ton Cooling air flow=602 cfm/ton <br /> Cooling at 70% SHR=2.7 ton Cooling at 400 cfm/ton=3.3 ton <br /> Overall U-Value=0.069 Btuh/ft?°F <br /> WARNING:window to floor area ratio=9.0%-less than 10%. <br /> Rightsuite ResidentialTM 5.0.64 RSR3o011 2006-Sep-19 11:44:08 <br /> wrjghtsoft <br /> ,�(;� C:\My Documents\Wrightsoft HVAC\H060919 DIESEN.rsr Page 1 <br />