Laserfiche WebLink
RIGHT-J SHORT FORM <br /> 6 Entire House <br /> Goodin Company Job: H060919 DIESEN <br /> 09-19-06 <br /> 285 Como Ave.,St.Paul,MN 55103-1862 Phone:651-489-8831 Fax:651-489-8837 Email:john.alberg@goodinco.com Web:www.goodinco.com <br /> Project • • <br /> For: SCOTT UNDERWOOD <br /> Design Information <br /> Htg Clg Infiltration <br /> Outside db(°F) -11 88 Method Simplified <br /> Inside db(°F) 70 75 Construction quality Average <br /> Design TD(°F) 81 13 Fireplaces 0 <br /> Daily range - M <br /> Inside humidity(%) - 50 <br /> Moisture difference(gr/Ib) - 22 <br /> HEATING EQUIPMENT COOLING EQUIPMENT <br /> Make Make <br /> Trade Trade <br /> qa+ <br /> Efficiency •89:9=13E Efficiency 0.0 EER <br /> Heating input 0 Btuh Sensible cooling 0 Btuh <br /> Heating output 0 Btuh Latent cooling 0 Btuh <br /> Heating temperature rise 0 °F Total cooling 0 Btuh <br /> Actual heating fan 1318 cfm Actual cooling fan 1318 cfm <br /> Heating air flow factor 0.026 cfm/Btuh Cooling air flow factor 0.053 cfm/Btuh <br /> Space thermostat Load sensible heat ratio 88 % <br /> ROOM NAME Area Htg load Clg load Htg AVF Clg AVF <br /> (ft2) (Btuh) (Btuh) (cfm) (cfm) <br /> BASEMENT 1794 21819 8590 567 459 <br /> MASTER BEDROOM 169 2998 1621 78 87 <br /> BEDROOM 2 127 2919 1585 76 85 <br /> BEDROOM 3 150 2510 1503 65 80 <br /> KITCHEN 173 2695 5692 70 304 <br /> DINING ROOM 456 10071 3326 262 178 <br /> LIVING ROOM 243 4586 1623 119 87 <br /> FOYER 68 1870 274 49 15 <br /> BATHS 176 1291 442 34 24 <br /> Printout certified by ACCA to meet all requirements of Manual J 7th Ed. <br /> wrightsoft Right-Suite Residential' 5.0.64 RSR30011 2006-Sep-19 11:44:08 <br /> ,BCCA C:\My Documents\Wrightsoft HVAC\H060919 DIESEN.rsr Page 1 <br />