, R <br /> Richard E.Eckroad.Inc. <br /> Consulting Structural Engineers 10130 36th Place North - Plymouth,Minnesota 68441 - (612)544-8599 <br /> January 19, 1999 Comm.No. 102-99 <br /> Mr. Bruce Schmitt <br /> Bruce Schmitt&Assoc. <br /> 320 Manitoba Ave.S. <br /> Wayzata, MN 55391 <br /> Re: House at 1040 Tonkawa Rd., Orono, MN <br /> Dear Sir, <br /> Reference is made to the design of the stair stringers for stair`B" in the above referenced home. <br /> The structural stringers shall be a 1/2 in. x 9 in. A36 steel plate by about 10 ft. long welded into <br /> a"dogleg", and bolted to the side of the 2 x 12 wood stair stringers and landing framing and ex- <br /> tending horizontally through the landing. Use 5/8 in. dia. bolts at 12 in. o.c. staggered up and <br /> down and add two additional bolts near the support points at each end and near the weld point. <br /> Use a full penetration weld plate to plate where the stair run meets the landing piece. Support at <br /> the ends is on beams or walls designed by others. <br /> Sincerly, <br /> Richard E. Eckroad P.E. <br /> Structural Engineer <br /> de <br />