My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2014-asbestos testing
Orono
>
Property Files
>
Street Address
>
T
>
Tonkawa Road
>
0755 Tonkawa Road - 05-117-23-33-0003
>
Misc
>
2014-asbestos testing
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:13:19 PM
Creation date
6/7/2019 10:54:16 AM
Metadata
Fields
Template:
x Address Old
Address
0755 Tonkawa Rd
Document Type
Misc
PIN
0511723330003
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LABORATORIES 1325 North 108th E.Ave. <br /> Tulsa,OK 74116 <br /> CERTIFICATION TESTING INSPECTION 918.437.8333 ph. 1918.437.8487tx. <br /> CLIENT: Nova Industries <br /> 8011 North 154th East Avenue <br /> Owasso, OK 74055 <br /> Attn: Tim Borgne <br /> Test Report No: TJ1409 -7Date:July 23, 2013 <br /> SAMPLE ID: The client submitted and identified the following test material as "Duct Armor" <br /> SAMPLING DETAIL: Test samples were submitted to the laboratory directly by the client. No special <br /> sampling conditions or sample preparation were observed by QAI. <br /> DATE OF RECEIPT: Samples were received at QAI on 6/20/13 <br /> TESTING PERIOD: July 1, 2013 <br /> AUTHORIZATION: Signed Proposal No. SP060713-2 <br /> TEST REQUEST®: Perform standard flame spread and smoke density developed classification tests on <br /> the sample supplied by the Client in accordance with ASTM E2768-11 "Standard Test <br /> Method for Extended Duration Surface Burning Characteristics of Building Materials <br /> 30 min Tunnel Test). This method is similar to UBC No. 8-1 per Chapter 7A of the <br /> 2001 California Building Code, Ignition-Resistant Material 30 minute test <br /> TEST RESULTS: Flame Spread Smoke Developed <br /> 10@10:00 30@10:00 <br /> Detailed test results are presented in the subsequent pages of this report <br /> PREPARED BY SIGNED FOR AND ON BEHALF OF <br /> QAI LABORATORIES, INC. <br /> David Bauchmoyer J. Brian McDonald <br /> Fre Test Technician Operations Manager <br /> Page 1 of 3 <br /> THIS REPORT IS THE CONFIDENTIAL PROPERTY OF THE CLIENT ADDRESSED.THE REPORT MAY ONLY BE REPRODUCED IN FULL.PUBLICATION OF EXTRACTS FROM THIS REPORT IS <br /> NOT PERMITTED WITHOUT WRITTEN APPROVAL FROM QAI.ANY LIABILITY ATTACHED THERETO IS LIMITED TO THE FEE CHARGED FOR THE INDIVIDUAL PROJECT FILE REFERENCED. <br /> THE RESULTS OF THIS REPORT PERTAIN ONLY TO THE SPECIFIC SAMPLE(S)EVALUATED. <br /> WWW.QAI.ORG <br /> info@gai.org <br />
The URL can be used to link to this page
Your browser does not support the video tag.