Laserfiche WebLink
17-3948 <br />July 17, 2017 <br />Page 3 of 7 <br />b. The property is directly adjacent to or across a public street from property which has <br />been developed previously as a RPUD or planned residential development and will be <br />perceived as and will function as an extension of that previously approved development. <br />c. The property is located in an area where the proposed development provides a transition <br />between a commercial or industrial area and an existing residential area or on an intermediate <br />or principal arterial as defined in the comprehensive plan. <br />(2) Uses. Each property rezoned to RPUD shall only be used for the use or uses for which the site is <br />designated in the comprehensive plan, except that the city may permit rezoning to RPUD on a <br />site designated for commercial use if the city council finds that such use is in the best interests <br />of the city and is consistent with the requirements of this division. If a commercial site is to <br />be rezoned to RPUD, the city may forward a copy of the request to the metropolitan council <br />for review. (emphasis added) <br />It would appear that the provisions of 78-626(1)b would be applicable, as the proposed use is within the <br />Stonebay Master Development and is directly across Kelley Parkway from the Stonebay Lofts, which are <br />similarly zoned RPUD. Further, because the site is guided for commercial office use with the intention of <br />being rezoned for commercial use, the rezoning would fit within the provisions of 78-626(2). It should be <br />noted that the Council has recently approved and supported two smaller RPUD developments (Shadywood <br />Villas and the Eisinger site) so that rezoning the Kelley Parkway parcel to RPUD would not be inconsistent. <br />Height limitations. "For properties guided for residential use in the comprehensive plan, a building <br />height limit of 30 feet shall apply. For properties currently zoned or guided in the comprehensive plan <br />for commercial use, height may exceed 30 feet but shall not exceed three stories (not including <br />underground parking level) and shall maintain a residential character by incorporating pitched or <br />hipped roof structure." <br />Architecture. The Stonebay development has established a certain design characteristic. Staff suggests that <br />the building materials be consistent with the pattern established by the Stonebay development, and include <br />architectural shingles, cement/ fiber boar siding, brick and/ or stone. These materials should be spelled out <br />in the final master plan. <br />Conformity: The proposed conceptual site plan includes a two-story building with a defined height <br />estimated at 32 feet, significantly lower than the Lofts across the street, but still technically requiring <br />flexibility. Proposed underground parking under half of the building constitutes a 3' level. It is assumed <br />that some filling to raise the overall elevation of the site is likely in order to accommodate the underground <br />RPUD District Minimum <br />SFR Standard <br />Proposedlot <br />Standards <br />Flexibility <br />Required? <br />Minimumproject size: <br />5 acres <br />3.5 <br />Yes <br />Building Setback (Kelley Parkway) <br />35 <br />44 <br />No <br />Building setback (Wayzata Blvd) <br />50 <br />54 <br />No <br />Minimum side yard setback: <br />35 feet <br />37 feet <br />No <br />Maximum FAR: <br />1 <br />0.52 <br />No <br />Parking lot and dribving lane setback <br />20' <br />8-27 feet <br />Yes <br />Private Recreational Area: <br />10% o f gro s s project area <br />3% proposed <br />Yes <br />Building height: <br />Maximum of 30 feet <br />appx32' <br />Yes <br />Number of stories <br />3 (Max) <br />2 <br />No <br />Hardcover <br />50% <br />63% <br />Yes <br />Height limitations. "For properties guided for residential use in the comprehensive plan, a building <br />height limit of 30 feet shall apply. For properties currently zoned or guided in the comprehensive plan <br />for commercial use, height may exceed 30 feet but shall not exceed three stories (not including <br />underground parking level) and shall maintain a residential character by incorporating pitched or <br />hipped roof structure." <br />Architecture. The Stonebay development has established a certain design characteristic. Staff suggests that <br />the building materials be consistent with the pattern established by the Stonebay development, and include <br />architectural shingles, cement/ fiber boar siding, brick and/ or stone. These materials should be spelled out <br />in the final master plan. <br />Conformity: The proposed conceptual site plan includes a two-story building with a defined height <br />estimated at 32 feet, significantly lower than the Lofts across the street, but still technically requiring <br />flexibility. Proposed underground parking under half of the building constitutes a 3' level. It is assumed <br />that some filling to raise the overall elevation of the site is likely in order to accommodate the underground <br />