Laserfiche WebLink
. . <br /> February 22,2012 <br /> 3025 Sixth Avenue North <br /> Page 2 of 2 <br /> Sec. 58-47. Building permit applications. <br /> (a) New residence. No building permit shall be issued for any new building that will be connected to <br /> an ISTS until a site evaluation and design is approved by the on-site systems manager. The site <br /> evaluation must include the identification of both primary and alternate drainfield sites suitable for <br /> a minimum of a five-bedroom residence. If the building will be connected to an existing system, a <br /> site evaluation and design must be approved by the city, including the existing system <br /> specifications and a future site meeting the provisions of this article. A new residence must be <br /> connected to an ISTS meeting the definition of a code system. <br /> (b) Required upgrade or rep/acement. A sewage treatment system not meeting the requirements of <br /> Minnesota Rules Chapter 7080, as amended, or the requirements of this article, whichever is <br /> more restrictive, must be upgraded, at a minimum, at any time a building permit is required for <br /> any improvements on, or use of, the property, subject to the following: <br /> (1) Any such system for which the city has previously issued orders requiring upgrade or <br /> replacement of the system by December 31, 2007, shall not be subject to this <br /> requirement until January 1, 2008. <br /> (2) Any such system for which the city has previously issued orders requiring upgrade or <br /> replacement of the system by December 31, 2010, shall not be subject to this <br /> requirement until January 1, 2011. <br /> (3) Regardless whether previous upgrade or replacement orders have been issued, this <br /> upgrade or replacement requirement shall not apply when said building permit is for <br /> regular maintenance or upkeep including but not limited to replacement of inechanical <br /> equipment such as air conditioning, furnaces, water heaters, or water softeners, or for re- <br /> roofing, re-siding or window replacement. <br /> (c) Construction of additional bedrooms or construction including water-using appliances that will <br /> increase the sewage flow into an lSTS. A building permit shall not be issued until the city confirms <br /> that the existing ISTS is compliant and of adequate size to treat the sewage flow from the building <br /> and that a future drainfield site is designed and preserved. If the existing ISTS must be repaired <br /> or replaced, an ISTS design for both the existing ISTS and a future drainfield site must be <br /> approved before issuing a building permit. If expansion or replacement of the ISTS is required, <br /> the ISTS must be installed and inspected before a certificate of occupancy shall be issued for the <br /> construction. Failure to identify satisfactory drainfield sites for the proposed sewage flow for use <br /> now as well as a future site shall result in the denial of the building permit application. <br /> (d) Expansion of an existing building, including decks and patios; construction of an accessory <br /> building, driveway or land alteration. A future drainfield site must be designed and preserved prior <br /> to the issuance of a building permit for any expansion of an existing building, construction to an <br /> accessory building or driveway or land alteration on a property using an ISTS. A building permit <br /> will not be issued when the proposed work would preclude the use of the only future drainfield <br /> site approved by the city. <br /> (Code 1984, § 12.30(4)(F); Ord. No. 100 2nd series, §4, 2-10-1992; Ord. No. 147 2nd series, § 8, 5-13-1996; Ord. <br /> No. 199 2nd series, § 1(12.30(4)(F)), 5-8-2000; Ord. No. 38 3rd series, § 1, 9-24-2007) <br />