Laserfiche WebLink
tLICLP Worldwide <br /> Contacts www.tyco-fire.com <br /> Series RFII — 5.6 K-factor <br /> "Royal Flush II" Concealed Pendent Sprinklers <br /> Quick & Standard Response, Standard Coverage <br /> General stallation or finish. The tip of the Pro- <br /> tective Cap can be used to mark the <br /> Description center of the ceiling hole into plaster <br /> p board or ceiling tiles by gently push- ?14 <br /> -4 <br /> The TYCO Series RFII 5.6 K-factor, ing the ceiling product against the Pro- <br /> tective Ca When ceilinginstallation <br /> "Royal Flush II" Concealed Pendent p Nd __ <br /> is complete, the Protective Capis re- <br /> Sprinklers Quick Response (3 mm movedandthe Cover Plate/ etainer <br /> bulb) and Standard Response (5-mm Assemblyis installed. <br /> bulb), are decorative sprinklers featur- <br /> ing a flat cover plate designed to con- As an option, the Series RFII Standard <br /> ceal the sprinkler.These sprinklers are Response(5-mm bulb)"Royal Flush II" <br /> optimal for architecturally sensitive ar- Concealed Pendent Sprinklers can be <br /> eas such as hotel lobbies, office build- fitted with a silicone Air and Dust Seal. 3 mm <br /> ings,churches, and restaurants. (Refer to Figure 5.) The Air and Dust • TY3531 ( Bulb) is UL Listed, <br /> Seal is intended for sensitive areas C-UL Listed, VdS Approved (Certif- <br /> Each sprinkler includes a Cover Plate/ icate No. G4090007), and NYC Ap- <br /> Retainer Assembly and a Sprinkler/ where it is desirable to prevent air and roved MEA 353-01-E) as Quick <br /> Support Assembly. The separa- dust from the area above the ceiling to p ( ) <br /> pp Cup y p ass throughResponse. <br /> ble, two-piece assembly design pro- p the cover plate. <br /> vides the following benefits: • TY3531 (3-mm Bulb) is FM and <br /> NOTICE LPCB Approved (Ref. No. 094a/10) <br /> • Allows installation of the sprinklers The Series RFII Concealed Pendent Approved as Standard Response. <br /> and pressure testing of the fire pro FactoryMutual and LPCB do not <br /> tection system prior to installation Sprinklers described herein must be approvany concealed sprinklers <br /> of a suspended ceiling lica- installed and maintained in compli- <br /> p g ora pp for quick response. <br /> tion of the finish coating to a fixed ance with this document and with the <br /> ceilin applicable standards of the National • TY3551 (5-mm Bulb) is UL Listed, <br /> g Fire Protection Association, in addi- C-UL Listed, FM Approved, LPCB <br /> • Permits the removal of suspended tion to the standards of any authori- Approved (Ref. No. 094a/9), and <br /> ceiling panels for access to building ties having jurisdiction. Failure to do so NYC Approved (MEA 353-01-E) as <br /> service equipment without having may impair the performance of these Standard Response. <br /> to first shut down the fire protection devices. <br /> system and remove sprinklers. Approvals for Air and Dust Seal <br /> The owner is responsible for maintain- <br /> • Provides for 1/2 inch (12,7 mm) of ing their fire protection system and de- UL and C-UL Listed for use with the <br /> vertical adjustment to allow a mea- vices in proper operating condition. RFII Standard Response Concealed <br /> sure of flexibility in determining the The installing contractor or sprinkler Sprinkler(TY3551). <br /> length of fixed piping to cut for the manufacturer should be contacted Maximum Working Pressure <br /> sprinkler drops. with any questions. <br /> The Series RFII Sprinklers are shipped Maximum 250 psi (17,3 bar) by UL, <br /> CUL, and NYC <br /> p <br /> with a Disposable Protective Cap.The Sprinkler <br /> Protective Cap is temporarily removed Maximum 175 psi (12,1 bar) by FM, <br /> during installation and replaced to help Identification VdS, and LPCB <br /> protect the sprinkler during ceiling in- Temperature Rating <br /> Number (SIN) 155°F(68°C)Sprinkler with <br /> IMPORTANT TY3531 — 3 mm bulb 139°F(59°C) Plate <br /> Always refer to Technical Data <br /> Sheet TFP700 for the "INSTALLER TY3551 — 5 mm bulb 200°F(93°C)Sprinkler with <br /> WARNING" that provides cautions 165°F(74°C) Plate <br /> with respect to handling and instal- Technical Discharge Coefficient <br /> lation of sprinkler systems and com- <br /> ponents. Improper handling and in- Data <br /> stallation can permanently damage Adjustment <br /> a sprinkler system or its components Sprinkler Approvals 1/2 inch (12,7 mm) <br /> and cause the sprinkler to fail to Approvals apply only to the service <br /> operate in a fire situation or cause it conditions indicated in the Design Cri Finishes <br /> to operate prematurely. teria section. See the Ordering Procedure section. <br /> Page 1 of 4 MARCH 2013 TFP181 <br />