TFP172 • <br /> Page 2 of 4 <br /> Components: *Temperature rating is ** Pipe thread connections per ISO 7-1 <br /> 1 - Frame 4 - Bulb indicated on Deflector. can be provided on special request. <br /> 2 - Button 5 - Compression STYLE 15 or 20 <br /> 3 - Sealing Screw ESCUTCHEON PLATE 1/2" 7/16"(11,1 mm) RECESSED <br /> Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON <br /> 6* I tirl ii9rT�, ffrrLIT-01, <br /> 5 �=' MIIM-7-- / <br /> 7/16" ■ R <br /> (11,1 mm) -- } u• c <br /> 4 I NOMINAL 2"W. I JD �� <br /> 2 WV I (50,8 mm) FrtERIII <br /> P': 2" <br /> N) 0/ 1-3/8" <br /> 3 w, r (50,8 mm) (34,9 mm) �_� <br /> WRENCH <br /> / I <br /> FLATS <br /> 1 4 <br /> 1 . <br /> 1/2" NPT** DEFLECTOR* — 2-7/8" (73,0 mm)DIA. <br /> CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT <br /> FIGURE 1 <br /> SERIES TY-FRB UPRIGHT(TY313)AND PENDENT(TY323)SPRINKLERS <br /> 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE <br /> G- Operation Installation <br /> The glass bulb contains a fluid which The TYCO Series TY-FRB,5.6 K-factor, <br /> WRENCH RECESS expands when exposed to heat. When Upright (TY313) and Pendent (TY323) <br /> (USE ONLY the rated temperature is reached, the Sprinklers must be installed in accor- <br /> END"A") fluid expands sufficiently to shatter the dance with this section. <br /> ^� glass bulb, allowing the sprinkler to <br /> activate and water to flow. General Instructions <br /> FIGURE 2 Do not install any bulb-type sprinkler if <br /> W-TYPE 6 the bulb is cracked or there is a loss <br /> SPRINKLER WRENCH Design of liquid from the bulb.With the sprin- <br /> kler held horizontally, a small air WRENCH bub- <br /> Criteria ble should be present. The diameter <br /> of the air bubble is approximately 1/16 <br /> RECESS The TYCO Series TY-FRB, 5.6 K-factor, inch (1,6 mm)for the 135°F(57°C) and <br /> Upright (TY313) and Pendent (TY323) 3/32 inch(2,4 mm)for the 286°F(141°C) <br /> ��1 Sprinklers are intended for fire protec- temperature ratings. <br /> /ice tion systems designed in accordance A leak tight 1/2 inch NPT sprinkler joint <br /> with the standard installation rules rec- <br /> ognized by the applicable Listing or should be obtained by applying a min- <br /> Approval agency (such as, UL Listing imum to maximum torque of 7 to 14 <br /> �' is based on the requirements of NFPA ft.-lbs. (9,5 to 19,0 Nm). Higher levels <br /> fir, 13, and FM Approval is based on the of torque can distort the sprinkler Inlet <br /> PUSH WRENCH requirements of FM's Loss Prevention with consequent leakage or impairment <br /> Data Sheets). Only the Style 15 or Style of the sprinkler. <br /> IN TO ENSURE 20 Recessed Escutcheon is to be used Do not attempt to compensate for <br /> ENGAGEMENT for recessed pendent installations. insufficient adjustment in the Escutch- <br /> WITH SPRINKLER <br /> WRENCHING AREA eon Plate by under-or over-tightening <br /> FIGURE 3 the sprinkler. Re-adjust the position of <br /> the sprinkler fitting to suit. <br /> W-TYPE 7 RECESSED <br /> SPRINKLER WRENCH Upright and Pendent Sprinklers <br /> The Series TY-FRB Upright and Pen- <br /> dent Sprinklers must be installed <br /> in accordance with the following <br /> instructions. <br /> Step 1.Install Pendent sprinklers in the <br /> pendent position. Install upright sprin- <br /> klers in the upright position. <br /> Step 2. With pipe-thread sealant <br /> applied to the pipe threads, hand- <br /> tighten the sprinkler into the sprinkler <br /> fitting. <br />